13.07.2015 Views

CJ2 CPU Unit Software User's Manual - CIP ETI

CJ2 CPU Unit Software User's Manual - CIP ETI

CJ2 CPU Unit Software User's Manual - CIP ETI

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

AppendicesWordsAddressBitsNameA401 A401.03 Card TransferError FlagA401.05 Version ErrorFlagA401.06 FALS Error Flag(Fatal error)A401.08 Cycle TimeExceeded Flag(Fatal error)A401.09 Program ErrorFlag(Fatal error)A401.10 I/O Setting ErrorFlag(Fatal error)A401.11 Too Many I/OPoints Flag(Fatal error)Function• ON when the contents of the Memory Card were not correctlyread into the <strong>CPU</strong> <strong>Unit</strong> when the power was turned ON.• ON when a program file (.OBJ) that includes network symbolsis transferred when the power is turned ON (<strong>CJ2</strong>H-<strong>CPU</strong>6@ and<strong>CJ2</strong>M-<strong>CPU</strong>1@ only.)ON when the unit version of the <strong>CPU</strong> <strong>Unit</strong> might not support theuser program that was transferred.ON when a non-fatal error is generated by the FALS(006) instruction.The <strong>CPU</strong> <strong>Unit</strong> will continue operating and the ERR/ALM indicatorwill flash.The corresponding error code will be written to A400. Error codesC101 to C2FF correspond to FALS numbers 001 to 511.ON: FALS(006) executedOFF: FALS(006) not executedThis flag will be turned OFF when the FALS errors are cleared.ON if the cycle time exceeds the maximum cycle time set in thePLC Setup (the cycle time monitoring time). <strong>CPU</strong> <strong>Unit</strong> operationwill stop and the ERR/ALM indicator on the front of the <strong>CPU</strong> <strong>Unit</strong>will light.OFF: Cycle time under max.ON: Cycle time over max.This flag will be turned OFF when the error is cleared.ON when program contents are incorrect.<strong>CPU</strong> <strong>Unit</strong> operation will stop and the ERR/ALM indicator on thefront of the <strong>CPU</strong> <strong>Unit</strong> will light. The task number where the erroroccurred will be stored in A294 and the program address will bestored in A298 and A299.The type of program error that occurred will be stored in bits 8 to15 of A295. Refer to the description of A295 and to the Programming<strong>Manual</strong> for more details on program errors.ON: ErrorOFF: No errorThis flag will be turned OFF when the error is cleared.• ON when the registered I/O tables do not match actual I/Otables (i.e., when the registered <strong>Unit</strong>s do not match the <strong>Unit</strong>sthat are actually connected).• With the <strong>CJ2</strong>H-<strong>CPU</strong>6@-EIP, ON when an Interrupt Input <strong>Unit</strong> ismounted in a slot other than those shown below.<strong>CJ2</strong>H-<strong>CPU</strong>6@-EIP: <strong>CPU</strong> Rack slots 0 to 3<strong>CJ2</strong>H-<strong>CPU</strong>6@ or <strong>CJ2</strong>M-<strong>CPU</strong>@@: <strong>CPU</strong> Rack slots 0 to 4• ON when the registered I/O tables for a <strong>CJ2</strong>H-<strong>CPU</strong>6@-EIP or<strong>CJ2</strong>M-<strong>CPU</strong>1@ <strong>CPU</strong> <strong>Unit</strong> are downloaded to a <strong>CJ2</strong>H-<strong>CPU</strong>6@ or<strong>CJ2</strong>M-<strong>CPU</strong>1@ <strong>CPU</strong> <strong>Unit</strong>, or when the registered I/O tables for a<strong>CJ2</strong>H-<strong>CPU</strong>6@ <strong>CPU</strong> <strong>Unit</strong> are downloaded to a <strong>CJ2</strong>H-<strong>CPU</strong>6@-EIP or <strong>CJ2</strong>M-<strong>CPU</strong>3@ <strong>CPU</strong> <strong>Unit</strong>. <strong>CPU</strong> <strong>Unit</strong> operation will stopand the ERR/ALM indicator on the front of the <strong>CPU</strong> <strong>Unit</strong> willlight.ON: ErrorOFF: No errorThis flag will be turned OFF when the error is cleared.ON when the number of I/O points being used in Basic I/O <strong>Unit</strong>sexceeds the maximum allowed for the PLC or when there aremore than 11 <strong>Unit</strong>s connected in one Rack.<strong>CPU</strong> <strong>Unit</strong> operation will stop and the ERR/ALM indicator on thefront of the <strong>CPU</strong> <strong>Unit</strong> will light.ON: ErrorOFF: No errorThis flag will be turned OFF when the error is cleared.Statusafter modechangeCleared forerror clearoperation.Cleared forerror clearoperation.Status atstartupCleared ---Cleared ---Cleared Cleared Refreshed whenerror occurs.A400Cleared Cleared Refreshed when thecycle time exceedsmaximum.PLC Setup (Cycletime monitoringtime)Cleared Cleared A294,A295,A298 and A299Cleared Cleared A405.08Cleared Cleared A407Write timing/Related flags, settingsA-118 <strong>CJ2</strong> <strong>CPU</strong> <strong>Unit</strong> <strong>Software</strong> User’s <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!