AppendicesWordsAddressBitsNameA402 A402.00 Other Non-fatalError Flag (SystemWork MemoryError)A402.02 Special I/O <strong>Unit</strong>Setting ErrorFlag(Non-fatal error)A402.03 <strong>CPU</strong> Bus <strong>Unit</strong>Setting ErrorFlag(Non-fatal error)Function• ON when a non-fatal error other than a non-fatal error allocatedto A402.01 to A402.15 occurs. (E.g., When an error occurs inmemory for online editing.)• Details of the other non-fatal errors are stored in A315.ON when an installed Special I/O <strong>Unit</strong> does not match the SpecialI/O <strong>Unit</strong> registered in the I/O table. The <strong>CPU</strong> <strong>Unit</strong> will continueoperating and the ERR/ALM indicator on the front of the <strong>CPU</strong> <strong>Unit</strong>will flash.ON: ErrorOFF: No errorThis flag will be turned OFF when the error is cleared.The unit number of the <strong>Unit</strong> where the setting error occurred isindicated in A428 to A433.ON when any of the following occur for a <strong>Unit</strong> registered in thesynchronous unit operation settings.• The <strong>Unit</strong> does not support the synchronous unit operation function.• The <strong>Unit</strong> is not connected in the PLC.• The <strong>Unit</strong> is not in the <strong>CPU</strong> Rack (i.e., it is in an ExpansionRack).The <strong>CPU</strong> <strong>Unit</strong> will continue operating and the ERR/ALM indicatoron the front of the <strong>CPU</strong> <strong>Unit</strong> will flash.ON: ErrorOFF: No errorThis flag will be turned OFF when the error is cleared and the correctPLC Setup is transferred to the <strong>CPU</strong> <strong>Unit</strong>.The unit number of the <strong>Unit</strong> where the setting error occurred isindicated in A428 to A433.ON when an installed <strong>CPU</strong> Bus <strong>Unit</strong> does not match the <strong>CPU</strong> Bus<strong>Unit</strong> registered in the I/O table. The <strong>CPU</strong> <strong>Unit</strong> will continue operatingand the ERR/ALM indicator on the front of the <strong>CPU</strong> <strong>Unit</strong> willflash.ON: ErrorOFF: No errorThis flag will be turned OFF when the error is cleared.The unit number of the <strong>Unit</strong> where the setting error occurred iswritten to A427Statusafter modechangeCleared forerror clearoperation.Status atstartupCleared ---Cleared Cleared A428 to A433Cleared Cleared A427Write timing/Related flags, settingsA-120 <strong>CJ2</strong> <strong>CPU</strong> <strong>Unit</strong> <strong>Software</strong> User’s <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!