13.07.2015 Views

ExpressCluster X 3.1 for Linux Getting Started Guide - Nec

ExpressCluster X 3.1 for Linux Getting Started Guide - Nec

ExpressCluster X 3.1 for Linux Getting Started Guide - Nec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 4 Latest version in<strong>for</strong>mationNumber4647484950515253Version (indetail) Upgraded section Cause<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1Suspending a user space monitor When WebManager was connectedsometimes failed if the monitoring to a server other than the mastermethod <strong>for</strong> user space monitoring server, the monitor status of thewas modified and uploaded when other servers was not checked.WebManager was connected to aserver other than the master server.The value of the EXEC resource An internal flag of “Prioritize failoverenvironmental variable CLP_EVENT, policy in the server group” wasis set to START instead of FAILOVER processed incorrectly.when the failover occurs <strong>for</strong> groups towhich “Prioritize the failover policywithin the server group” is set.The monitor resource startup status A internal flag of “Prioritize failoverwas not restored when failover was policy in the server group” wasper<strong>for</strong>med <strong>for</strong> groups to which processed incorrectly.“Prioritize failover policy in the servergroup” is set.Recovery action counts were not Shared memory values were reset,reset by the clpmonctrl command but values saved in the memory ofwhen the monitor error recovery monitor resource processes are notaction was fully executed.reset.When a server is added while BMC or In<strong>for</strong>mation to be added anda warning light is set, the BMC and associated with the server additionwarning light are not set to the new was insufficient.server in<strong>for</strong>mation.Cluster Generation Wizard was In the processing of cancellingstarted and two servers were added Cluster Generation Wizard, not allto a cluster. After that, the wizard was data was discarded.cancelled (but the settings weresaved). Then, the add a server wizardwas started but a server was notdisplayed on the interconnectconfiguration screen.If a license error occurs while A thread which was processing NPprocessing NP resolution when resolution was cancelled when astopping the cluster due to a license cluster was stopped by a licenseerror, sometimes the cluster does not error, but the thread was deadnormally stop.locked because of cancelling thelocked thread.The name of a server cannot be fully A horizontal scroll bar was notdisplayed in the list of available displayed.servers in the server tab of groupproperties.54<strong>3.1</strong>.0-1/ 3.0.0-1 to3.0.4-1Mirror commands (such as When an internal command wasexecutions by using sudo commands executed, there was a location thatand script executions by using did not reference an absolute path.crond) from the root user did not runproperly when a path to an OSstandard command (such as/usr/sbin/) was not taken..90<strong>ExpressCluster</strong> X <strong>3.1</strong> <strong>for</strong> <strong>Linux</strong> <strong>Getting</strong> <strong>Started</strong> <strong>Guide</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!