31.07.2015 Views

IFC 110 F V2.0 IFC 110 F-EEx V2.0 - Krohne

IFC 110 F V2.0 IFC 110 F-EEx V2.0 - Krohne

IFC 110 F V2.0 IFC 110 F-EEx V2.0 - Krohne

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Sect. 14 Part E Index14 IndexKeyword Sect. No. Fct. No. Keyword Sect. No. Fct. No.A External totalizer 2.3, 2.6, 5.7 1.06, 1.07A1 status or 2nd pulse output 2.3, 2.6, 1.07, 3.075.7, 5.18 FA1/A2 status outputs 2.4, 2.6, 5.10 1.07, 1.08 F = forward flow 4.4, 5.1, 5.15 1.04-1.07, 3.02Abbreviations 1.3.2, 1.3.4, Factory setting(s) 2.72.1, 4.1, 4.4 Fatal error 4.5ADC see analog/digital converter FE = functional grounding conductor 1.1, 1.2, 1.3.3Additional function = option 6.2, 6.4, 10.1 1.3.5, 1.3.6Analog/digital converter 4.5, 11 Field current supply 5.13, 10.1Applications 5.17 3.06 11, 12Automatic range change 2.6, 5.20 1.05, 1.07-1.10 Flow– pulsating 6.5, 6.6 3.06B – quickly changing 6.6, 6.7Bar magnet 4.2, 6.2, 8.2 Flow constant GK 4.4, 5.13 3.02Block diagram 12 Flow direction 4.4, 5.1, 5.15 3.02BTS, bootstrap signal line B 1.3 Flow rate (Q) 4.4, 5.1 3.02Flow sensorC – constant GK 4.4, 5.13 3.02C1/C2 control inputs 2.5, 2.6, 5.9 1.11, 1.12 – replacement 8.5Cable length 1.3.4 – testing 7.6Characteristic of outputs 5.16 Flow simulator GS 8 A 7.7Code for entering setting level 5.12 3.04 Flow velocity (v) 4.4, 5.1 3.03Connection and operating points 4.2 Frequency output see pulse output 2.3, 5.7 1.06– front panel 8.7 Full-scale range Q100% 4.4, 5.1 1.01, 3.02– printed circuit boards Functional checkConnection diagrams – hardware information 7.3 2.02– GS 8 A simulator 7.7 – measuring range 7.2– inputs/outputs 2.6 – primary head 7.6– power supply 1.3.5, 1.3.6 – signal converter 7.7– primary head 1.3.5, 1.3.6 – setpoint readings 7.7Control inputs C 2.5, 4.4, 5.9 – system 7.5Conversion factor 4.4, 5.14 – zero 7.1 3.03– volume 4.4, 5.14 3.05 Functional grounding conductor FE 1.1, 1.2, 1.3.3– time 3.05 1.3.5, 1.3.6Current output I 2.2, 5.6 Function level 4.1 1.01 et seq.,2.01 et seq.,D3.01 et seq.D1/D2 status outputs 2.4, 2.6, 5.8 1.09, 1.10 Function of keys 4.1, 4.3Data 4.4 Function(s) 4.4Data error 4.5 Fuses (F) 8.1, 8.7, 9Data level 4.1-4.3Delete error messages 4.6 GDimensions 10.3 GK primary head constant 4.4, 5.13 3.02Disconnection 2.1 GroundingDisplay 4.2, 5.5 1.04 – primary head 1.3.3– language 4.4, 5.11 3.01 – signal converter 1.2, 1.3– unsteady 6.6 – system 1.2-1.3DS signal line A 1.3 GS 8 A primary simulator 7.7EHE+/E- internal power supply forHardwareinputs/outputs 2.1, 2.5, 5.10 – information 7.3 2.02EC electronic totalizer 2.3, 2.6, 5.9 1.06 – setting(s) 5.18 3.07<strong>EEx</strong> version 1.3.6, 6.1, 10.1 – test 7.4 2.03Electrical connection HART ® interface 6.4.2– GS 8 A simulator 7.7 Hazardous areas 1.3.6, 6.1, 10.1– inputs 2.6 page 5– outputs 2.6– power supply 1.3.5, 1.3.6 IElectromagnetic compatibility page 5 I = current output 2.2, 5.6 1.05Electromechanical totalizer 2.3, 5.7 1.07, 3.07 IEC standards page 5Electronic totalizer 2.3, 5.7 1.06 IMoCom bus (plug) 6.4, 8.7, 11EMC electromechanical totalizer 2.3, 2.6 ImoCom software 6.4.15.7, 5.17 1.07, 3.06 Inputs/outputsEmpty pipe detection EPD 6.9 – characteristics 5.16Entry (programming) 4 – connection diagrams 2.6EPD (empty pipe detection) 6.9 – setting 4.4Error 4.5 — control inputs 5.9 1.11, 1.12Error list 4.5 — current output 5.6 1.05Error (messages) — pulse outputs 5.7 1.06, 1.07, 3.07– eliminate 4.5 — status outputs 5.8 1.07-1.10, 3.07– limits 10.1 – steady voltage with empty tube 5.7– reset (delete) 4.6 Interfaces 6.4, 10.1– search 7.1 et seq. Intermediate connection box (ZD) 1.4, 10.3EU standards page 5 Internal power supply (E+/E-) 2.1, 2.6, 5.10100 <strong>IFC</strong> <strong>110</strong> F 05/2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!