Part A System installation and start-up Sect. 1.3.21.3.2 Stripping (preparation) of signal cablesPlease note: The numbers in the drawings designate the stranded drain wires of signalling cablesA and B, see sectional drawings in Sect. 1.3.1.Flow sensorConverterLength flow sensor Length Convertermm inch mm incha 90 3.60 a 50 2.00b 8 0.30 b 8 0.40c 25 1.00 d 8 0.40d 8 0.30 e 20 0.80e 70 2.80Signal cable A (type DS),double shieldingfor flow sensorSignal cable A (type DS),double shieldingfor <strong>IFC</strong> <strong>110</strong> F ConverterSignal cable Abending radius≥ 50 mm (≥ 2”)Signal cable Abending radius≥ 50 mm (≥ 2”)Signal cable B (type BTS),with triple shielding (bootstrap)for flow sensorSignal cable B (type BTS),with triple shielding (bootstrap)for <strong>IFC</strong> <strong>110</strong> F ConverterSignal cable Bbending radius≥ 50 mm (≥ 2”)Signal cable Bbending radius≥ 50 mm (≥ 2”)Customer-supplied materialsW Insulation tubing (PVC), Ø 2.0-2.5 mm (Ø 1”)X Heat-shrinkable tubing or cable sleeveY Wire end sleeve to DIN 41 228: E 1.5-8Z Wire end sleeve to DIN 41 228: E 0.5-805/2003 <strong>IFC</strong> <strong>110</strong> F 9