31.07.2015 Views

IFC 110 F V2.0 IFC 110 F-EEx V2.0 - Krohne

IFC 110 F V2.0 IFC 110 F-EEx V2.0 - Krohne

IFC 110 F V2.0 IFC 110 F-EEx V2.0 - Krohne

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Part D Technical Data, Measuring Principle and Block Diagram Sect. 10.1Status outputs (passive) D1 / D2 / A2 A1 (can also be operated as pulse output)Function, set for trip point trip pointflow directionflow directionautomatic range change automatic range changeerror identificationerror identificationoverdrivingoverdrivingempty pipelineempty pipelineTerminals D1 / D2 / D ⊥ / A2 / A ⊥ A1 / A ⊥Please note: D ⊥ common reference potential for D1 and D2A ⊥ common reference potential for A1 and A2Electrical data galvanically isolated galvanically isolated, but not from A2U ≤ 32 V DC / ≤ 24 V AC U ≤ 32 V DC / ≤ 24 V ACI ≤ 100 mA, any polarity I ≤ 100 mA, any polarityor U ≤ 32 V DC, I ≤ 200 mA, note polarityControl inputs C1 and C2 (passive)Function, set forautomatic range change, totalizer reset, error reset, start self-test,set outputs to min. values or hold last measured values of outputsTerminalsC1 / C ⊥ and C2 / C ⊥, galvanically isolatedPlease note: C ⊥ common reference potential for C1 and C2U = 8 – 32 V DC, I ≤ 10 mA, any polarityInternal power supplyfor passive outputs and inputs and external receiver instrumentsTerminalsE + and E –, please note polarity, galvanically isolatedElectrical dataU = 24 V DC / R i = approx. 15 Ohm / I ≤ 100 mATime constant0.2 – 99.9 s, adjustable in increments of 0.1 secondLow-flow cutoff cutoff ”on“ value: 1 – 19 %cutoff ”off“ value: 2 – 20 %} of Q 100% , adjustable in 1% incrementsLocal display and operation3-line back-lit LCDDisplay functionactual flowrate, forward, reverse, sum totalizers (7 digits)or 25-character bar graph with percent display and status messagesUnits: actual flowrate m³/h, liter/s., US gallons/min or user-defined unit, e. g. hecto liter/htotalizerm³, liter, or US gallons or user-defined unit (adjustable counting time till overflow)Language of plain textsEnglish, German, French, Swedish, others on requestDisplay: 1st line 8-character, 7-segment, numerical and sign display,and symbols for key acknowledgement2nd line10-character, 14-segment, text display3rd line6 markers to identify display in measuring modeOperation elements15 keys or as option with 3 additionally magnetic sensors for operation withoutopening the housingElectrode circuitType of protectionintrinsic safety [<strong>EEx</strong> ib IIC]Max. values (cumulative)U 0 = 18 V / I 0 = 40 mA / P 0 = 80 mWKinked characteristiccapacitance C 0 ≤ 225 nF / inductance L 0 ≤ 5 mHField power supplyTypepulsed bipolar DC field for all KROHNE primary heads,galvanically isolated from all input and output circuitsTerminals 2 x 7 and 8Current / voltage± 0.125 A (± 5%) / U N ≤ 40 V DC (frequency controlled)Clock frequency1 / 36 to ½ of power frequency,configurable to the calibration data of the primary headInternal fuse protectionI N ≤ 160 mAPower supply AC version AC / DC version (switch-selectable)standardoption, in preparationVoltage range (without change over) 100 – 230 V AC 24 V AC 24 V DCTolerance band 85 – 255 VAC 20.4 – 26.4 V AC 18 – 31.2 V DCSafety value U m = 253 V U m = 253 V U m = 253 VFrequency 48 – 63 Hz 48 – 63 Hz –Power consumption (incl. primary head) 18 VA, typical (max. 25 VA) 18 VA, typical (max. 25 VA) 18 W, typical (max. 18 W)When connected to a functional extra-low voltage, 24 V AC / DC, protective separation (PELV) must beensured (VDE 0100 / VDE 0106 and IEC 364 / IEC 536 or equivalent national standards).Approvals and housingMaterial of field housingdie-cast aluminium with polyurethane finishAmbient temperature • operation standard -25 to +60 °C / -13 to +140 °F<strong>EEx</strong> -20 to +55 °C / - 4 to +131 °F<strong>EEx</strong>, special “S” -40 to +55 °C / -40 to +131 °F• storage all versions -40 to +60 °C / -40 to +140 °FProtection category (IEC 529 / EN 60 529) IP 65, equivalent to NEMA 4 / 4XEU_EMC Directives to EN 61326-1 (1977) and A1 (1998) directives and NAMUR Standard NE 21Certificates and approvalsII (2) G [<strong>EEx</strong> ib] IICPTB 02 ATEX 2136 X05/2003 <strong>IFC</strong> <strong>110</strong> F 89

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!