Part A System installation and start-up Sect. 2.72.7 Standard factory settings• All operating data are set at the factory in accordance with the specifications contained in theorder.• If no specifications are made in the order, instruments will be delivered with the standardparameters and functions indicated in the table below.• To facilitate the start-up of the instrument, current and pulse outputs are set to handlemeasurements in ”two flow directions” so that the current flow rates and volumes are displayedand/or counted independent of the direction of flow. The figures displayed may have apreceding sign.• Such factory setting of current and pulse outputs may lead to measuring errors, particularlywhen volumes are metered and totalized.• If e.g. pumps are switched off and ”backflows” occur which are not within the low-flow cutoff(SMU) range, or if separate displays and counts are required for both flow directions.• To avoid faulty measurements, it may therefore be necessary to change the setting of thefollowing functions:- SMU low-flow cutoff Fct. 1.03, Section 5.3- display Fct. 1.04, Section 5.5- current output I Fct. 1.05, Section 5.6- pulse output P Fct. 1.06, Section 5.7• For special applications, such as pulsating flows, see Sections 6.5 to 6.10Standard factory settingsFct. No. Function Setting Fct. No. Function Setting1.01 Full-scale range See instr. nameplate 1.08 Status output A2 ONof flow sensor 1.09 Status output D1 All error1.02 Time constant 3 Sec. for display, 1.10 Status output D2 Indication F/Rpulse, current and 1.11 Control input C1 Totalizer resetstatus ouputs 1.12 Control input C2 OFF1.03 Low-flow cutoff ON: 1% 3.01 Language GermanOFF: 2% 3.02 Flow sensor1.04 Display meter size See instr. nameplateflow rate m³/h direction of flow + direction,totalizer m³ see arrow on1.05 Current output I active flow sensorfunction 2 directions 3.04 Entry code NOrange 4-20 mA 3.05 User unit Liter/herror detection 22 mA 3.06 Application1.06 Pulse output P flow steadyfunction 2 directions empty pipe NOpulse value 1000 pulses/Sec. ADC gain automaticpulse width symmetric special filter OFF1.07 Pulse output 2, A1 3.07 Hardwarefunction 2 directions terminal A1 pulse output A1pulse value 1 pulse/s selfcheck NOpulse width 50 ms05/2003 <strong>IFC</strong> <strong>110</strong> F 25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!