Part B <strong>IFC</strong> <strong>110</strong> F Signal converter Sect. 5.8→ PULSWIDTH = select pulse width, press → key• AUTO (automatic = 50 % of cycle duration of 100 % output frequency)• SYM. (symmetric = pulse duty factor 1:1 across entire range)• SEC. (variable) setting range 0.01 - 1.00 SECSelect with ↑ and ↓ keys.Press → key to change to numerical setting.Change flashing number (cursor) with keys ↑ and ↓ . Use → and ← keys to shift cursor1 place to right or left.Flashing numbers (cursor) can also be directly set with the 10-key keyboard.Press ↵ key to change to subfunction ”VALUE P” and/or ”VALUE P2”.→ VALUE P = set pulse value per unit volumeonly appears when ”PULSE/VOL.” is selected in ”SELECT P”, press → key• XXXX PulS/m³• XXXX PulS/litre• XXXX PulS/US.Gal• XXXX PulS/user-defined unit, factory setting = ”Liter” or ”US MGal/day”, see Section 5.14Select with ↑ and ↓ keys.Press → key to change to numerical setting, 1st number (cursor) flashes.Set numerical value• XXXX (setting range depends on pulse width and full-scale range:P min = F min / Q 100% P max = F max / Q 100% )Change flashing number (cursor) with keys ↑ and ↓ . Use → and ← keys to shift cursor1 place to right or left.Flashing numbers (cursor) can also be directly set with the 10-key keyboard.Press ↵ key to return to Fct. 1.06 PULS P or to Fct. 1.07 PULS2 A1.→ VALUE P = set pulse value per unit timeonly appears when ”PULSE/TIME” is selected in ”SELECT P”, press → key• XXXX PulSe/Sec• XXXX PulSe/min• XXXX PulSe/h• XXXX PulSe/user-defined unit, factory setting = ”h” or ”day”, see Section 5.14Select with ↑ and ↓ keys.Press → key to change to numerical setting, 1st number (cursor) flashes.Set numerical value• XXXX (setting range depends on pulse width)Change flashing number (cursor) with keys ↑ and ↓ . Use → and ← keys to shift cursor1 place to right or left.Flashing numbers (cursor) can also be directly set with the 10-key keyboard.Press ↵ key to return to Fct. 1.06 PULS P or to Fct. 1.07 PULS2 A1.orPlease refer to Section 2.7 ”Factory settings”.Refer to Section 2.6 for connection diagrams and to Section 5.16 for characteristics.05/2003 <strong>IFC</strong> <strong>110</strong> F 45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!