Table 6–1. EC LODs <strong>and</strong> LOQs for 25- <strong>and</strong> 37-mm filters (ug EC/cm 2 )25-mm filter EC (n = 10) 37-mm filter EC (n = 6)Mean 0.063 Mean 0.033St<strong>and</strong>ard deviation 0.030 St<strong>and</strong>ard deviation 0.028LOD 0.09 LOD 0.08LOQ 0.30 LOQ 0.28Table 6–2. OC LODs <strong>and</strong> LOQs for 25- <strong>and</strong> 37-mm filters (ug OC/cm 2 )25-mm filter OC (n = 10) 37-mm filter OC (n = 6)Mean 1.41 Mean 1.94St<strong>and</strong>ard deviation 0.413 St<strong>and</strong>ard deviation 0.281LOD 1.24 LOD 0.84LOQ 4.13 LOQ 2.81Table 6–3. OC, EC, <strong>and</strong> TC LODs <strong>and</strong> LOQs for 37-mm filters (ug C/cm 2 )37-mm filter OC EC OC EC TCMean 1.31 0.03 1.44 0.03 1.52St<strong>and</strong>ard deviation 0.164 0.016 0.304 0.024 0.318LOD 0.49 0.05 0.91 0.07 0.95LOQ 1.64 0.16 3.04 0.24 3.18As stated on previous page, NIOSH Method 5040LOD depends on the air volume, filter size, sampleportion analyzed (usually 1.5 cm 2 ), <strong>and</strong> the mediablank variability. The latter is used <strong>to</strong> determine theLOD in unit’s µg/cm 2 . Expressed as an air concentration,the EC LOD (µg/m 3 ) corresponding <strong>to</strong> theEC LOD (µg/cm 2 ) determined with media blanks(i.e., LOD = 3 times the st<strong>and</strong>ard deviation for theblanks) can be calculated by the following equation:This equation explains why a lower LOD (µg/m 3 )can be obtained by reducing the filter size (depositarea), increasing the air volume, <strong>and</strong> minimizingthe variability for the media blanks (i.e., the ECLOD in µg/cm 2 ). The LOD is improved using asmaller filter size since the deposit density is higherfor an equivalent mass deposited. The same applies<strong>to</strong> the LOQ, commonly defined as 10 timesthe st<strong>and</strong>ard deviation (SD) for the blanks, or 3.3times the LOD.If 0.02 µg EC/cm 2 is taken as the SD for mediablanks (with manual OC-EC split adjustment),the LODs <strong>and</strong> LOQs (in µg EC/m 3 ) for different56 NIOSH CIB 65 • <strong>Carbon</strong> <strong>Nanotubes</strong> <strong>and</strong> <strong>Nanofibers</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!