19.08.2015 Views

Occupational Exposure to Carbon Nanotubes and Nanofibers

Occupational Exposure to Carbon Nanotubes and Nanofibers

Occupational Exposure to Carbon Nanotubes and Nanofibers

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

air volumes, 25-mm <strong>and</strong> 37-mm filters, <strong>and</strong> a1.5 cm 2 filter portion analyzed would be as listedin Table 6–4. Results for a SD double this value(i.e., SD = 0.04 µg EC/cm 2 ) also are reported asworst-case estimates, but are seldom this high. IfSDs for media blanks are frequently above 0.02ug EC/cm 2 ) the cause of the high blank variabilityshould be identified <strong>and</strong> corrected.Based on EC results for media blanks (Tables 6–1<strong>and</strong> 6–3), a filter loading of about 0.3 µg/cm 2 (i.e.,at or above the EC LOQs reported in Tables 6–1<strong>and</strong> 6–3) will provide quantitative results.As described above (6.1.2), higher flow rate respirablesamplers (cyclones) with a 25 mm cassettecan improve the sample collection <strong>to</strong> permitmeasurement of CNT <strong>and</strong> CNF above the LOQ(i.e., 1 µg/m 3 ) for samples collected for less thanfull work shift. Examples of sampling periods <strong>and</strong>flow rates that provide air volumes of about a halfcubicmeter or higher (shaded area in table below)are listed in Table 6–5. A larger filter portion alsocan be used <strong>to</strong> further lower the LOD, but the instrument’ssmall (quartz tube) oven <strong>and</strong> need forproper sample alignment limit the amount of samplethat can be analyzed.Table 6–4. EC LODs <strong>and</strong> LOQs estimated with media blanksEC LOD <strong>and</strong> LOQ (µg EC/m 2 )3 m 3 air 1 m 3 air 0.5 m 3 airSD blank(µg EC/cm 2 )LimitEC limit(µg/cm 2 )37-mmfilter25-mmfilter37-mmfilter25-mmfilter37-mmfilter25-mmfilter0.02 LOD 0.06 0.17 0.07 0.51 0.21 1.02 0.42LOQ 0.20 0.57 0.23 1.70 0.69 3.40 1.380.04 LOD 0.12 0.34 0.14 1.02 0.42 2.04 0.83LOQ 0.40 1.13 0.46 3.40 1.38 6.80 2.77Table 6–5. Examples of sampling periods <strong>and</strong> flow ratesAir volumes (m 3 ) for indicated sampling periods (hours) <strong>and</strong> flow ratesFlow rate (lpm) † 1 h ‡ 2 h 4 h 8 h2 120 240 480 9604 240 480 960 19206 360 720 1440 28807 420 840 1680 3360†Liters per minute (lpm).‡Sampling period, hours, <strong>and</strong> highest flow rate tested at NIOSH labora<strong>to</strong>ry. Tested with a Lel<strong>and</strong> Legacy pump <strong>and</strong> 25-mmquartz-fiber filter.NIOSH CIB 65 • <strong>Carbon</strong> <strong>Nanotubes</strong> <strong>and</strong> <strong>Nanofibers</strong>57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!