Document No.: SIG-00-97-08 Version: C<br />

1-5<br />

INTRODUCTION<br />

been correctly associated with the Approval Listing printout. If no corruption is detected, an<br />

approved MCF is created and a Unique Check Number (UCN) is calculated using the contents of<br />

the MCF and the selected Module Executable File (MEF) for the <strong>HD</strong>/LINK I/O Module. You can<br />

print the group Installation Listing and the I/O Module Wiring List. The Installation Listing<br />

contains the configuration information of the Approved MCF. The Wiring List contains the I/O<br />

Module wiring configuration.<br />

Following its approval, the MCF may be transferred (copied) to the DTU for I/O Module installation.<br />

Once the MCF has been successfully copied to the DTU, the UCN may be manually entered into the<br />

DTU, as required. During this transfer function, the selected version of the MEF may also be copied<br />

to the DTU. This allows the MEF resident in the I/O Module to be updated as required.<br />

During the module installation process, the <strong>HD</strong> Link I/O Module calculates an In Service Check<br />

Number. When this number is manually returned to the MCF Manager and entered, the status of<br />

the MCF is changed from Approved to In Service. When the I/O Module is taken out of service, it<br />

calculates an Out of Service Check Number. When this number is entered into the MCF Manager,<br />

the status of the MCF is changed from In Service to Out of Service.<br />

1.1.4 Event Log<br />

The Event Log file records all significant <strong>HD</strong>/<strong>LINKer</strong> events. Yuo can view or print the contents of<br />

the event log.<br />

1.2 APPLICABLE DOCUMENTS<br />

• Application Guidelines, <strong>HD</strong>/LINK Vital I/O Module, 53201<br />

(Safetran Document #SIG-00-97-05)<br />

• Installation Handbook, <strong>HD</strong>/LINK Vital I/O Module, A53201<br />

(Safetran Document #SIG-00-97-07)<br />

• Installation and Maintenance, R/LINK ATCS Radio Code Line System<br />

(Safetran Document #COM-00-94-03)<br />

1.3 SYSTEM REQUIREMENTS<br />

<strong>HD</strong>/<strong>LINKer</strong> requires the following minimum configuration:<br />

• VGA monitor<br />

• 200 MHz Pentium