14- <strong>Motor</strong> Auto-Tune Parameters<br />

Function<br />

Code No.<br />

LCD<br />

Display<br />

Description Range/Code<br />

4-20<br />

Chapter 4 Software Index<br />

Factory<br />

Setting Remarks<br />

14-0 (Stator Resistor) Stator Resistance (Ohms) ----- *3*5<br />

14-1 (Rotor Resistor) Rotor Resistance (Ohms) ----- *3*5<br />

14-2 (Equi Inductance) Equivalent Inductance (mH) ----- *3*5<br />

14-3 (Magnet Current)<br />

Magnetizing Current (Amps<br />

AC)<br />

----- *3*5<br />

14-4 (Ferrite Loss) Ferrite Loss Conductance (gm) ----- *3*5<br />

15- Drive Status and Function Reset<br />

Function<br />

Code No.<br />

LCD<br />

Display<br />

Description Range/Code<br />

Factory<br />

Setting Remarks<br />

15-0 (Drive Model) Drive Horsepower Code (See page 4-53) *3<br />

15-1 (Software Version) Software Version ----- ----- *3<br />

15-2 (Fault Log) Fault Jog (Last 3 Faults) (See page 4-53) ----- *3<br />

15-3 (Elapsed Hours)<br />

Accumulated Operation Time<br />

(Hours)<br />

0 - 9999 ----- *3<br />

15-4<br />

Accumulated Operation Time<br />

(Elapsed Hr*10000)<br />

(Hours X 10000)<br />

0 - 27 ----- *3<br />

15-5 (Elapsed Time Sel)<br />

Accumulated Operation Time<br />

Mode<br />

15-6 (Reset Parameter) Reset Drive to Factory Settings<br />

※Notes: *1 can be modified during operation<br />

0000: Time Under Power<br />

0001: Run Mode Time Only<br />

1110: Reset for 50 Hz <strong>Motor</strong><br />

Operation<br />

1111: Reset for 60 Hz <strong>Motor</strong><br />

Operation<br />

1112: Reset PLC Program<br />

*2 cannot be modified during communication<br />

*3 do not change while making factory setting<br />

*4 as parameter related to factory setting<br />

*5 the parameter will be changed by replacing model (see descriptions of the<br />

POSTSCRIPT 1)<br />

*6 only available in V/F mode<br />

*7 only for version 2.3 and above.<br />

*8 only for version 2.4 and above.<br />

*9 for 15HP of 220V class and 20HP of 440V class above<br />

0000 *3<br />

0000 *4