14- <strong>Motor</strong> Auto-Tune Parameters<br />
Function<br />
Code No.<br />
LCD<br />
Display<br />
Description Range/Code<br />
4-20<br />
Chapter 4 Software Index<br />
Factory<br />
Setting Remarks<br />
14-0 (Stator Resistor) Stator Resistance (Ohms) ----- *3*5<br />
14-1 (Rotor Resistor) Rotor Resistance (Ohms) ----- *3*5<br />
14-2 (Equi Inductance) Equivalent Inductance (mH) ----- *3*5<br />
14-3 (Magnet Current)<br />
Magnetizing Current (Amps<br />
AC)<br />
----- *3*5<br />
14-4 (Ferrite Loss) Ferrite Loss Conductance (gm) ----- *3*5<br />
15- Drive Status and Function Reset<br />
Function<br />
Code No.<br />
LCD<br />
Display<br />
Description Range/Code<br />
Factory<br />
Setting Remarks<br />
15-0 (Drive Model) Drive Horsepower Code (See page 4-53) *3<br />
15-1 (Software Version) Software Version ----- ----- *3<br />
15-2 (Fault Log) Fault Jog (Last 3 Faults) (See page 4-53) ----- *3<br />
15-3 (Elapsed Hours)<br />
Accumulated Operation Time<br />
(Hours)<br />
0 - 9999 ----- *3<br />
15-4<br />
Accumulated Operation Time<br />
(Elapsed Hr*10000)<br />
(Hours X 10000)<br />
0 - 27 ----- *3<br />
15-5 (Elapsed Time Sel)<br />
Accumulated Operation Time<br />
Mode<br />
15-6 (Reset Parameter) Reset Drive to Factory Settings<br />
※Notes: *1 can be modified during operation<br />
0000: Time Under Power<br />
0001: Run Mode Time Only<br />
1110: Reset for 50 Hz <strong>Motor</strong><br />
Operation<br />
1111: Reset for 60 Hz <strong>Motor</strong><br />
Operation<br />
1112: Reset PLC Program<br />
*2 cannot be modified during communication<br />
*3 do not change while making factory setting<br />
*4 as parameter related to factory setting<br />
*5 the parameter will be changed by replacing model (see descriptions of the<br />
POSTSCRIPT 1)<br />
*6 only available in V/F mode<br />
*7 only for version 2.3 and above.<br />
*8 only for version 2.4 and above.<br />
*9 for 15HP of 220V class and 20HP of 440V class above<br />
0000 *3<br />
0000 *4