5-00~5-05=06 Jog command Off Off On<br />
5-00~5-06=04<br />
Toggle Acc/Dec time.<br />
Off On Off<br />
4-28<br />
Chapter 4 Software Index<br />
5.)When S curve time (3-04/3-05) is set as 0, the S curve is useless. Namely, acceleration and deceleration<br />
is at line.<br />
6.)When S curve time (3-04/3-05) is larger than 0, the acceleration and deceleration action is as following<br />
diagram.<br />
7.)Regardless of the stall prevention period, actual acceleration and deceleration time =preset acceleration<br />
/ deceleration time + S curve time. For example: acceleration time = 3-03+ 3-04.<br />
8.)During acceleration and deceleration process, there might be residual error in acceleration and<br />
deceleration toggling. Please set the S curve time as 0 (3-04/3-05), if you need to toggle acceleration<br />
and deceleration time in acceleration / deceleration process.<br />
Output frequency<br />
3-10 : DC Injection Brake Start Frequency (Hz) : 0.1 – 10.0<br />
3-11 : DC Injection Brake Level (%) : 0.0 – 20.0<br />
3-12 : DC Injection Brake Time(second) : 0.0 – 25.5<br />
3-12 / 3-10 is the action time and start frequency of DC braking, as graph below:<br />
HZ<br />
3-10<br />
S C ti<br />
The upper setting of 3-11 will be corrected 20.0 after manual V2.3.<br />
3-13 : Skip Frequency #1 (Hz) : 0.00 –650.00<br />
3-14 : Skip Frequency #2 (Hz) : 0.00 –650.00<br />
3-15 : Skip Frequency #3 (Hz) : 0.00 –650.00<br />
3-16 : Skip Frequency Bandwidth (± Hz) : 0.00 –30.00<br />
Example: as 3-13is set as 10.0Hz / 3-14 as 20.0 Hz / 3-15a s 30.0 Hz / 3-16 as 2.0Hz<br />
3-12<br />
10Hz ±2Hz=8-12Hz<br />
20Hz ±2Hz=18-22Hz skip frequency<br />
30Hz ±2Hz=28-32Hz<br />
3-16<br />
Time<br />
t