02.03.2013 Views

CV7300 Instruction Manual - TECO-Westinghouse Motor Company

CV7300 Instruction Manual - TECO-Westinghouse Motor Company

CV7300 Instruction Manual - TECO-Westinghouse Motor Company

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The motor can not run<br />

YES<br />

Is MCCB<br />

applied?<br />

Can MCCB be<br />

applied?<br />

Are voltages<br />

between power<br />

terminals correct?<br />

Is LED 101lit?<br />

Are there outputs between<br />

U,V,W terminals of the motor<br />

Are outputs between<br />

U,V,W even<br />

˙<strong>Motor</strong><br />

˙<strong>Motor</strong> faults<br />

˙Bad wiring<br />

NO<br />

Is the operation switch<br />

in “RUN’ position<br />

YES (within ±10% of the normal value)<br />

YES<br />

Chapter 5 Troubleshooting and maintenance<br />

Short circuited wiring<br />

˙The power is abnormal<br />

˙Bad wiring<br />

YES (voltage deviation between pairs are even if within ±3%<br />

of the normal value without the motor connected)<br />

5-12<br />

NO<br />

NO<br />

NO<br />

NO<br />

NO<br />

NO<br />

7300CV fault<br />

The operation switch is set to<br />

“RUN’ position<br />

7300CV fault<br />

7300CV fault