CV7300 Instruction Manual - TECO-Westinghouse Motor Company
CV7300 Instruction Manual - TECO-Westinghouse Motor Company
CV7300 Instruction Manual - TECO-Westinghouse Motor Company
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Chapter 4 Software Index<br />
7-05 (AI2 Gain) AI2 Gain (%)(S6) 0 - 200 100 *1<br />
※ Notes: Group 7 is available when 5-06=0023 (AIN term.=Analog input)<br />
8- Multifunction Output Relays and Output Signal Operation<br />
Function<br />
Code No.<br />
LCD<br />
Display<br />
8-00 (AO Mode Sel)<br />
Description Range/Code<br />
Analog Output Voltage Mode<br />
(0 - 10 VDC, Term. FM+)<br />
4-16<br />
0000: Output Frequency<br />
0001: Frequency Setting<br />
0002: Output Voltage<br />
0003: DC Voltage<br />
0004: Output Current<br />
0005: PID Feedback *7<br />
Factory<br />
Setting Remarks<br />
0000 *1<br />
8-01 (AO Gain) Analog Output Gain (%) 0 - 200 100 *1<br />
8-02 (Relay R1 Sel)<br />
8-03 (Relay R2 Sel)<br />
Output Relay R1 Operation<br />
Mode<br />
Output Relay R2 Operation<br />
Mode<br />
8-04 (Freq Agree)<br />
Frequency Reached (Hz)<br />
(Refer to 8-02: 0001)<br />
8-05<br />
Frequency Reached Bandwidth<br />
(Freq Agree width)<br />
(± Hz)<br />
9- Drive and Load Protection Modes<br />
Function<br />
Code No.<br />
LCD<br />
Display<br />
9-00 (Trip ACC Sel)<br />
9-01 (Trip ACC Level)<br />
9-02 (Trip DEC Sel)<br />
Description Range/Code<br />
Trip Prevention Selection<br />
During Acceleration<br />
Trip Prevention Level During<br />
Acceleration (%)<br />
Trip Prevention Selection<br />
During Deceleration<br />
0000: Run<br />
0001: Frequency Reached<br />
(Frequency Command) (Set<br />
Frequency ± 8-05)<br />
0002: Set Frequency (8-04 ± 8-05)<br />
0003: Frequency Threshold Level (><br />
8-04) - Frequency Reached<br />
0004: Frequency Threshold Level (<<br />
8-04) - Frequency Reached<br />
0005: Over torque Threshold Level<br />
0006: Fault<br />
0007: Auto Restart<br />
0008: Momentary AC Power Loss<br />
0009: Rapid Stop Mode<br />
0010: Coast-to-Stop Mode<br />
0011: <strong>Motor</strong> Overload Protection<br />
0012: Drive Overload Protection<br />
0013: PID Feedback Signal Loss<br />
0014: PLC Operation<br />
0015: Power On *7<br />
0006<br />
0000<br />
0.00 - 650.00 0.00 *1<br />
0.00 - 30.00 2.00 *1<br />
0000: Enable Trip Prevention During<br />
Acceleration<br />
0001: Disable Trip Prevention<br />
During Acceleration<br />
50 - 300<br />
0000: Enable Trip Prevention During<br />
Deceleration<br />
0001: Disable Trip Prevention<br />
During Deceleration<br />
Factory<br />
Setting Remarks<br />
0000<br />
200<br />
150*9<br />
0000