9-03 (Trip DEC Level)<br />

9-04 (Trip RUN Sel)<br />

9-05 (Trip Run Level)<br />

9-06 (Dec Sel Trip RUN)<br />

9-07<br />

(Dec Time Trip<br />

RUN)<br />

9-08 (<strong>Motor</strong> OL1 Sel)<br />

Trip Prevention Level During<br />

Deceleration (%)<br />

Trip Prevention Selection in<br />

Run Mode<br />

Trip Prevention Level In Run<br />

Mode (%)<br />

Trip Prevention Deceleration<br />

Time Selection in Run Mode<br />

Deceleration Time In Trip<br />

Prevention Mode (Seconds)<br />

Electronic <strong>Motor</strong> Overload<br />

Protection Operation Mode<br />

9-09 (<strong>Motor</strong> Type) <strong>Motor</strong> type Selection<br />

9-10 (<strong>Motor</strong> OL1 Curve)<br />

9-11 (<strong>Motor</strong> OL1 Operat)<br />

<strong>Motor</strong> Overload Protection<br />

Curve Selection<br />

Operation After Overload<br />

Protection is Activated<br />

9-12 (Torq Det Sel) Over torque Detection Selection<br />

9-13 (Torq Det Operat)<br />

9-14 (Torq Det Level)<br />

9-15 (Torq Det Delay)<br />

Operation After Over torque<br />

Detection is Activated<br />

Over torque Threshold Level<br />

(%)<br />

Over torque Activation Delay<br />

Time (Seconds)<br />

4-17<br />

Chapter 4 Software Index<br />

200<br />

50 - 300<br />

150*9<br />

0000: Enable Trip Prevention in Run<br />

Mode<br />

0000<br />

0001: Disable Trip Prevention in<br />

Run Mode<br />

200<br />

50 - 300<br />

150*9<br />

0000: Trip Prevention Deceleration<br />

Time Set by 3-03<br />

0000<br />

0001: Trip Prevention Deceleration<br />

Time Set by 9-07<br />

0.1 – 3600.0 3.0<br />

0000: Enable Electronic <strong>Motor</strong><br />

Overload Protection<br />

0001: Disable Electronic <strong>Motor</strong><br />

Overload Protection<br />

0000: Electronic <strong>Motor</strong> Overload<br />

Protection Set for<br />

Non-Inverter Duty <strong>Motor</strong><br />

0001: Electronic <strong>Motor</strong> Overload<br />

Protection Set for Inverter<br />

Duty <strong>Motor</strong><br />

0000: Constant Torque (OL =103 %)<br />

(150 % for 1 Minute)<br />

0001: Variable Torque (OL = 113 %)<br />

(123 % for 1 Minute)<br />

0000: Coast-to-Stop After Overload<br />

Protection is Activated<br />

0001: Drive Will Not Trip when<br />

Overload Protection is<br />

Activated (OL1)<br />

0000: Disable Over torque Operation<br />

0001: Enable Over torque Operation<br />

Only if at Set Frequency<br />

0002: Enable Over torque Operation<br />

while the Drive is in Run<br />

Mode<br />

0000: Drive will Continue to<br />

Operate After Over torque is<br />

Activated<br />

0001: Coast-to-Stop After Over<br />

torque is Activated<br />

0000<br />

0000<br />

0000<br />

0000<br />

0000<br />

0000<br />

30 - 200 160<br />

0.0 - 25.0 0.1