0050BE 50 37.0 68.0 80 125 150<br />

0060BE 60 45.0 82.0 96 150 200<br />

0075BE 75 55.0 110.0 128 200 250<br />

*Fuse ratings are based upon 250V fuses for 230V inverter, and 600V for 460V inverters<br />

To avoid shock hazards, do not touch any electrical component when the power is applied or<br />

just after five minutes the power plug is unplugged. The other action should be performed<br />

after the charge indicator went off.<br />

Do not perform wiring on the inverter while it is still electrified. Disregard of this notice<br />

could cause serious injure or death to persons.<br />

※This product is designed to use in Pollution Degree 2 environment or equivalent environments.<br />

3.3.2 Applicable specification of magnetic contactor and wires<br />

Molded-case circuit breaker/magnetic contactor<br />

Teco bears no responsibility to service for failures caused by the following conditions:<br />

(1) A molded-case circuit breaker is not installed, or an improper or overrated breaker is<br />

used, between the power source and the inverter.<br />

(2) A magnetic contactor, a phase capacitor, or a burst absorber is connected between the<br />

inverter and the motor.<br />

7300CV model<br />

JNTHBCBA□□□□AC / JNTHBCBA□□□□BC<br />

Molded-case<br />

circuit breaker<br />

made by Teco<br />

Magnetic<br />

contactor (MC)<br />

made by Teco<br />

Main circuit<br />

terminals<br />

(TM1)<br />

Signal terminals<br />

(TM2)<br />

7300CV model<br />

Molded-case circuit<br />

breaker made by Teco<br />

Magnetic contactor<br />

(MC) made by Teco<br />

Main circuit terminals<br />

(TM1)<br />

R500 0001 0002 0003 0005 7R50 0010 0015 0020 0025 0030 0040<br />

TO-50E<br />

10A<br />

TO-50E<br />

20A<br />

Wire gauge<br />

2.0 mm 2<br />

TO-50E<br />

30A<br />

TO-50E<br />

30A<br />

TO-50E<br />

30A<br />

TO-50E<br />

50A<br />

TO-100S<br />

60A<br />

TO-100S<br />

100A<br />

TO-100S<br />

100A<br />

TO-225S<br />

150A<br />

TO-225S<br />

175A<br />

TO-225S<br />

175A<br />

CN-11 CN-16 CN-18 CN-25 CN-50 CN-65 CN-80 CN-100 CN-125<br />

Wire gauge<br />

3.5 mm 2<br />

Wire gauge 5.5<br />

mm 2<br />

Wire<br />

gauge<br />

14 mm 2<br />

Wire gauge 0.75mm 2 ( # 18 AWG)<br />

JNTHBCBA□□□□BE<br />

Wire gauge<br />

22 mm 2<br />

Wire<br />

gauge<br />

38mm 2<br />

Wire<br />

gauge<br />

60mm 2<br />

0001/ 0002/ 0003/ 0005 7R50 0010 0015 0020 0025 0030 0040 0050 0060 0075<br />

TO-50E<br />

15A<br />

TO-50E<br />

20A<br />

TO-50E<br />

30A<br />

TO-50E<br />

50A<br />

TO-100S<br />

50A<br />

TO-100S<br />

75A<br />

TO-100S<br />

100A<br />

TO-100S<br />

100A<br />

TO-125S<br />

125A<br />

TO-225S<br />

175A<br />

TO-225S<br />

175A<br />

CN-11 CN-16 CN-18 CN-25 CN-35 CN-50 CN-50 CN-65 CN-80 CN-100 CN-125<br />

Wire gauge 2.0mm 2<br />

Wire gauge<br />

3.5mm 2<br />

Wire<br />

gauge<br />

5.5mm 2<br />

Wire gauge<br />

8mm 2<br />

Wire<br />

gauge<br />

14mm 2<br />

Wire gauge<br />

22mm 2<br />

Wire<br />

gauge<br />

38mm 2<br />

Wire<br />

gauge<br />

60mm 2