Chapter 4 Software Index<br />

1.RS-485 Communication:<br />

(1)1 vs 1 Controlling: to control one inverter by a PC or PLC or controller.(set 13-0 = 1~254)<br />

(2)1 vs more Controlling: to control more than one inverters by PC or PLC or Controller (The max<br />

number of inverter could be 254. set 13-0 = 1~254), when the inverter receives the communication<br />

station code = 0, the communication controlling is acceptable regardless the setting value of 13-0.<br />

2. RS-232communication: (RS232 interface is required)<br />

1vs1 controlling: to control one inverter by a PC or PLC or controller. (Set 13-0 = 1~254)<br />

※Note:<br />

a. The BAUD RATE (13-1) of PC (or PLC or Controller) and the one of the inverter should be set as<br />

the same .Communication format (13-2/13-3/13-4) should be set as the same.<br />

b. The inverter will confirm the parameter efficient as PC modifies the parameter of the inverter.<br />

c. Please refer to the 7300CV Communication PROTOCOL.<br />

14-0: Stator Resistance(Ohms) Gain<br />

14-1: Rotator Resistance(Ohms) Gain<br />

14-2: Equivalent Inductance(mH) Gain<br />

14-3: Magnetized Current(Amps AC) Gain<br />

14-4: Ferrit Loss Conduction (gm) Gain<br />

Parameter Group 14 - Auto Tuning<br />

1. If 0-00=0 or 1(vector mode ) is selected, as power ON, set 0-06=1, the motor will run as the<br />

inverter performs auto tuning. As the motor stop, it means that auto tuning finished. The inverter<br />

will write the internal parameter of the motor to 14-0~ 14-4, and auto reset the 0-06 as 0.<br />

2. Auto tuning must be carried out as long as the motor changed. If the internal parameters is known<br />

already, they can be input to 14-0~14-4 directly.<br />

3. 0-06=1,to perform auto tuning, after finished, 0-06 auto reset to 0, the Keypad displays END.<br />

4.The parameter group only affect the current vector.<br />

Parameter Group 15 - Operation Status and Function Reset<br />

15-0: Drive Horsepower Code<br />

15-0 Inverter Model 15-0 Inverter Model<br />

2P5 R500AC/BC 401 JNTHBCBA 0001BE<br />

201 0001AC/BC 402 0002BE<br />

202 0002AC/BC 403 0003BE<br />

203 0003AC/BC 405 0005BE<br />

205 0005BC 408 7R50BE<br />

208<br />

210<br />

JNTHBCBA<br />

7R50BC<br />

0010BC<br />

410<br />

415<br />

0010BE<br />

0015BE<br />

215 0015BC 420 0020BE<br />

220 0020BC 425 0025BE<br />

225 0025BC 430 0030BE<br />

230 0030BC 440 0040BE<br />

240<br />

0040BC 450<br />

0050BE<br />

4-57