4-50<br />
Chapter 4 Software Index<br />
※Note: Over torque output signal will be output as the parameter 9-12=0001or 0002 when the level and<br />
time are over the range.<br />
V/F PATTERN Selection<br />
Parameter Group 10 – Volts /Hz Pattern Operation Mode<br />
10-0: V/F PATTERN Selection = 0 – 18<br />
10-1: Torque boost gain(V/F pattern modulation)% = 0.0 – 30.0%<br />
10-2: <strong>Motor</strong> no load current(Amps AC) -------------<br />
10-3: <strong>Motor</strong> rated slip compensation(%) = 0.0 – 100.0%<br />
10-4: Max output frequency(HZ) = 0.20 – 650.0Hz<br />
10-5: Max output frequency voltage ratio(%) = 0.0 – 100.0%<br />
10-6: Medium frequency(HZ) = 0.10 –650.0Hz<br />
10-7: Medium output frequency voltage ratio (%) = 0.0 – 100.0%<br />
10-8: Min output frequency(HZ) = 0.10 –650.0Hz<br />
10-9: Min output frequency voltage ratio (%) = 0.0 – 100.0%<br />
1. 10-0=18, set the V/F pattern freely complying with 10-4~10-9 (Refer to following diagram)<br />
10-5<br />
(Vmax)<br />
10-7<br />
(Vmid)<br />
10-9<br />
(Vmin)<br />
(V)<br />
10-8 10-6 10-4 650<br />
Hz