10-0 B<br />

Chapter 4 Software Index<br />

C<br />

0 / 9 50.0% 1.0%<br />

1 / 10 60.0% 1.0%<br />

2 / 11 65.0% 1.0%<br />

3 / 12 70.0% 1.0%<br />

4 / 13 40.0% 1.0%<br />

5 / 14 35.0% 1.0%<br />

6 / 15 45.0% 1.0%<br />

7 / 16 55.0% 1.0%<br />

8 / 17 65.0% 1.0%<br />

3. The inverter will output the value that B, C voltage (refer to 10-0) plus 10-1 V/F pattern setting.<br />

And the start torque will be raised.<br />

10-1=<br />

100%<br />

1<br />

25/3<br />

※Note: 10-1=0, Torque boost function is invalid<br />

4. When the induction motor is in running, there must be slip due to the load. It is necessary to boost to<br />

improve the precision of the speed.<br />

Output Current-(10-2) Note : 0-02=motor rated current<br />

Slip frequency boost =<br />

× (10-3)<br />

(0-02)-(10-2)<br />

10-2=motor no load current<br />

10-3 rough value= (<strong>Motor</strong> synchronization speed– Rated speed) / <strong>Motor</strong> synchronization speed<br />

Marked on the motor nameplate<br />

<strong>Motor</strong> synchronization speed (RPM)=<br />

120<br />

<strong>Motor</strong> Poles<br />

× <strong>Motor</strong> rated frequency (50Hz or 60Hz)<br />

eg: 4 Poles,60Hzinduction motor synchronization speed =<br />

B<br />

C<br />

Voltag<br />

4-52<br />

120<br />

4<br />

× 60=1800 RPM<br />

※Note: <strong>Motor</strong> no load current(10-2) differs with the inverter capacities(15-0)(Refer to 0-02 note),<br />

It should be regulated according to the actual condition.<br />

50/6<br />

Hz