Check_Bolt_Shear := "Sufficient Strength" if Tbolt_shear ≥ Tn_blowout Weld Design<br />

"Insufficient Strength" otherwise<br />

Weld Connecting Annular Plate to Pipe<br />

tpipe = 0.47 in<br />

Check_Bolt_Shear = "Sufficient Strength"<br />

3<br />

Weld_Size<br />

8 in := AISC Spec. J2<br />

Table J2.4<br />

Felectrode := 70ksi<br />

FW := .6⋅Felectrode AISC Spec. J2<br />

Table J2.5<br />

Throat := .707⋅Weld_Size Rn_weld := Throat⋅FW Rn_weld 11.14 kip<br />

= ⋅<br />

in<br />

Rn_yield := .6⋅Fy_pipe⋅tpipe Rn_yield 11.72 kip<br />

= ⋅<br />

in<br />

Rn_rupture := .45⋅Fu_pipe⋅tpipe Rn_rupture 12.14 kip<br />

= ⋅<br />

in<br />

Rn := min( Rn_weld, Rn_yield, Rn_rupture) Rn 11.14 kip<br />

= ⋅<br />

in<br />

Rweld := Rn⋅π⋅d pipe<br />

Rweld = 559.72 kip<br />

dpipe Tweld := Rweld⋅ T<br />

2<br />

weld = 373.15 ft·kip<br />

dpipe Mweld := Rweld⋅ M<br />

2<br />

weld = 373.15 ft·kip<br />

Base Connection<br />

Tn_s_pipe = 359.1 ft·kip<br />

Tweld = 373.15 ft·kip<br />

Mweld = 373.15 ft·kip<br />