Increase threaded rod diameter to 2 in<br />

Diameterthreadedrod := 2in<br />

Pmax.bolthole := 2.4⋅Diameterthreadedrod⋅tbaseplate.pole⋅fu.baseplate = 453.792 kip<br />

( )<br />

Check_bearing := if Pn.bolthole ≤ Pmax.bolthole, "Sufficient" , "Not Sufficient"<br />

Size the leveling nuts<br />

Use Heavy Hex nuts<br />

Wlevel.nut := 3.125in AISC Table 7-20<br />

Clevel.nut := 3.625in AISC Table 7-20<br />

Nlevel.nut := 2in<br />

AISC Table 7-20<br />

Base Connection Design<br />

Embedded Pipe Design<br />

Step 2) Embedded Pipe Design<br />

Given<br />

ϕflex = 0.9<br />

Diameterbase.pole = 16⋅in ϕweld := .75<br />

twall.pole = 0.375⋅in fy.pipe := 42ksi<br />

Diameterbaseplate.pole = 30⋅in fu.pipe := 58ksi<br />

tbaseplate.pole = 1.63⋅in fy.baseplate := 36ksi<br />

Diameterboltcircle.pole = 23⋅in fu.baseplate := 58ksi<br />

Es 2.9 10 4<br />

= × ⋅ksi<br />

Vu = 9.04 kip<br />

Tu = 198.88 ft·kip<br />

Mu = 165.34 ft·kip<br />

Size the cross section of the embedded pipe<br />

Diameterembed.pipe := Diameterbase.pole = 16⋅in twall.embed.pipe := twall.pole = 0.375⋅in 185<br />

Check_bearing = "Sufficient"