<strong>Service</strong> <strong>Manual</strong> Safety Summary 5<br />
Braun Thermoscan PRO 4000<br />
SpO 2 Warnings<br />
These warnings are specific to the Braun ThermoScan PRO 4000 thermometer option.<br />
WARNING Keep the probe window clean, dry, and undamaged at all times to<br />
ensure accurate measurements. To protect the probe window, always keep the<br />
thermometer in the storage cover while transporting or when not in use.<br />
WARNING Only use Braun ThermoScan probe covers with this thermometer.<br />
Using other manufacturer’s probe covers or no probe cover may produce<br />
temperature measurement errors and/or inaccuracies. If the thermometer is used<br />
without a probe cover attached, clean the lens (see “Braun ThermoScan PRO<br />
4000 Thermometer” on page 78).<br />
WARNING Do not autoclave.<br />
WARNING The thermometer is not waterproof. Do not immerse or drip fluids<br />
on it. Should this occur, dry the thermometer with warm air. Check for proper<br />
operation and accuracy.<br />
These warnings pertain to the <strong>Spot</strong> <strong>LXi</strong> SpO 2 feature.<br />
WARNING Only use <strong>Spot</strong> <strong>LXi</strong> with Masimo or Nellcor SpO 2 option with Masimo<br />
or Nellcor brand sensors and accessories, respectively. Using the wrong or<br />
unapproved sensors or cables may cause improper performance.<br />
WARNING The SpO 2 sensor and extension cables are intended for use only for<br />
pulse oximetry measurements. Do not attempt to connect these cables to a PC<br />
or any similar device.<br />
WARNING Before using, carefully read the sensor Directions for Use, including<br />
all warnings, cautions, and instructions.<br />
WARNING Do not use a damaged sensor or pulse oximetry cable or a sensor<br />
with exposed optical components.<br />
WARNING Incorrect application or a long duration of use of an SpO 2 sensor may<br />
cause tissue damage. Inspect the sensor site periodically as directed in the<br />
sensor’s Directions for Use.<br />
WARNING Certain ambient environmental conditions, sensor application errors,<br />
and certain patient conditions may affect SpO 2 readings and pulse signal.<br />
WARNING Do not immerse the sensor or patient cables in water, solvents, or<br />
cleaning solutions (the sensors and connections are not waterproof). Do not use<br />
irradiation, steam, or ethylene oxide for sterilization.<br />
WARNING The SpO 2 in the <strong>Spot</strong> <strong>LXi</strong> device is not intended for use as an apnea<br />
monitor.<br />
WARNING Consider the SpO 2 an early warning device. As a trend toward<br />
patient deoxygenation is indicated, use laboratory instruments to analyze blood<br />
samples to completely understand the patient’s condition.