SENDLIST.DYNAMIC (SLDYN)<br />

When data is downloaded<br />

When a SENDLIST.DYNAMIC; command is executed at runtime, your dynamic list box<br />

data is prepared for downloading to PowerClient. This data:<br />

$ Applies to data items with the LISTBOX; or LISTBOX*; Data Attribute<br />

$ Is stored in the PowerClient repository, for use whenever the named list box is<br />

required for a screen format<br />

$ Is downloaded to PowerClient or NOF:<br />

v At end of transaction<br />

v When a SLEEP; or CRITICAL.POINT; command is executed in a Report initiated<br />

from a PowerClient or NOF terminal<br />

v On MCP based target hosts, when an Ispec in another Subsystem is recalled<br />

For OS 2200 Based <strong>LINC</strong> Systems<br />

For an OS 2200 based <strong>LINC</strong> System, move the transaction ID for WDP into GLB.STN before<br />

executing the SENDLIST.DYNAMIC; command. In addition, you should note the following<br />

consideration when using large dynamic listboxes.<br />

Large dynamic listboxes<br />

Large dynamic listboxes (greater than 2000 entries of 30 characters) on 2200 Series hosts<br />

can cause severe network congestion. This may result in the PCE station not receiving all<br />

the listbox information. If the information cannot be delivered, it is discarded by the<br />

standard (non-<strong>LINC</strong>) host communications software.<br />

To avoid network congestion, perform one of the following:<br />

$ Make the listbox static (using the SENDLIST.STATIC; command)<br />

$ Adjust the CMS1100 configuration parameter MAX-QUEUE-ENTRIES (default is 10).<br />

This defines the maximum depth of messages that can be queued to a terminal before<br />

the MCB discards the information. For the impact of changing this parameter, see your<br />

Communications Management System (CMS 1100) Configuration <strong>Reference</strong><br />

<strong>Manual</strong>.<br />

Format of the Data<br />

The SENDLIST.DYNAMIC; command downloads a single alphanumeric value. This value<br />

consists of a number of parts - referred to as columns - separated by delimiters.<br />

How the various columns are used is determined by your PowerClient application. See<br />

your PowerClient documentation for further details.<br />