18.08.2013 Views

LINC Programming Reference Manual - Public Support Login - Unisys

LINC Programming Reference Manual - Public Support Login - Unisys

LINC Programming Reference Manual - Public Support Login - Unisys

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

START (ST)<br />

To avoid duplication, <strong>LINC</strong> will only restart jobs in Ispec or Report recovery, where those<br />

START; commands were apparently not successfully executed for those jobs prior to the<br />

failure. START; commands that were successfully executed prior to the failure will be<br />

ignored.<br />

If the failure is due to a system halt/load, the MCP will automatically restart all jobs that<br />

were active at the time of the interruption.<br />

The chargecode that applies to your WFL start is dependent on the values of the :COD <strong>LINC</strong><br />

System command and the GLB.CHARGECODE System Data item. For further details, see<br />

$ ‘‘GLB.CHARGECODE’’, in this manual<br />

$<br />

$<br />

"Setting Chargecodes for <strong>LINC</strong> Systems and Reports" in your MCP Based <strong>LINC</strong><br />

Administration and Operations Guide<br />

"Report and WFL Job Chargecodes" in your MCP Based <strong>LINC</strong> Administration and<br />

Operations Guide<br />

For an OS 2200 based <strong>LINC</strong> System<br />

The START; command executes an OS 2200 based ECL runstream. The request is passed to<br />

the <strong>LINC</strong> Background Run which performs an @START of the runstream. Consequently,<br />

the run is executed under the same account/userid as the <strong>LINC</strong> Background Run.<br />

No status is returned on the success or otherwise of the runstream.<br />

There is only one parameter for the START; command. This is the element name of the<br />

runstreams. No parameters can be passed to the runstream.<br />

All runstreams to be accessed by the START; command must be copied into the following<br />

file:<br />

<br />

GLB.STATUS is set to indicate the result of the START; command, as shown in the<br />

following table.<br />

Value Result Indicated<br />

INVAL The runstream cannot be located.<br />

Space The <strong>LINC</strong> Background Run has been instructed to start the runstream. If for some<br />

reason it cannot be started, EXEC will reject the START command from the <strong>LINC</strong><br />

Background Run, the runstream will not be started, and <strong>LINC</strong> logic will not receive<br />

error notification.<br />

1-242 v

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!