SENDLIST.STATIC (SLSTA)<br />

SENDLIST.STATIC (SLSTA)<br />

The SENDLIST.STATIC; command enables PowerClient users to use specific Ispec data<br />

item list boxes whose values are created by a host <strong>LINC</strong> System. This command is<br />

designed to be used with PowerClient (Designer Workbench). The use of this command<br />

with NOF is also supported.<br />

In a Report, you can create a file of list box items by using the EXTRACT; command and<br />

then name the file by using the SENDLIST.STATIC; command. When an Ispec screen is<br />

displayed in PowerClient, a data item that has the LISTBOX; Data Attribute is displayed as<br />

a static list box containing the data downloaded by the SENDLIST.STATIC; command.<br />

The first time each user accesses the file, it is downloaded.<br />

About List Boxes<br />

For a description of the types of list boxes, see ‘‘About List Boxes’’ under<br />

‘‘SENDLIST.DYNAMIC (SLDYN)’’, earlier in this section.<br />

You can modify the format, size and location of the list box when you are using<br />

PowerClient during the screen design process.<br />

Availability of the Command<br />

The SENDLIST.STATIC; command is not available with OLTP.<br />

For MCP Based <strong>LINC</strong> Systems<br />

For Reports run from a NOF terminal or program for an MCP based <strong>LINC</strong> System, the<br />

SENDLIST.STATIC; command sends data to the NOF terminal or program. Otherwise, the<br />

data is submitted to the Workstation Driver Program (WDP).<br />

For Ispecs in an MCP based <strong>LINC</strong> System, executing the SENDLIST.STATIC; command<br />

from a T27 style, IBM 3270 or OLTP terminal is ignored unless contained in the System<br />

Global Logic STARTUP (in which case the data is submitted to WDP). NOF input results in<br />

the data being sent to the NOF terminal or program.<br />

For OS 2200 Based <strong>LINC</strong> Systems<br />

For OS 2200 based <strong>LINC</strong> Systems, the SENDLIST.STATIC; command has an effect only in<br />

Ispecs or Reports initiated by a PowerClient station, or in standalone Reports.<br />

For UNIX <strong>LINC</strong> Systems<br />

For UNIX <strong>LINC</strong> Systems, the SENDLIST.STATIC; command has an effect only in Ispecs or<br />

Reports initiated by a PowerClient station, or in standalone Reports.<br />