SWITCH.TO (SWT)<br />

$ On OS 2200 based <strong>LINC</strong> Systems, if the INHERIT; command option had been used<br />

when the SWITCH.TO; was executed, you can use the System Data items<br />

GLB.ORIGINPTN, GLB.ORIGINISPEC, and GLB.ORIGINXNID to switch back to the<br />

originating <strong>LINC</strong> System.<br />

In the destination <strong>LINC</strong> System, the values of these System Data items are defined if<br />

the SWITCH.TO; command was executed with the INHERIT; command option. The<br />

values of these System Data items are initialized to spaces if you access another Ispec<br />

in the destination system.<br />

Note: You must target another PCE application when you use the<br />

SWITCH.TO command from a PCE station. Switching to a <strong>LINC</strong><br />

window with data, if that window is not another PCE application,<br />

will result in the receiving non-PCE window receiving error<br />

messages about non-PCE format input. Further input from the PCE<br />

station receives the message; "Transmission inhibited as a<br />

transaction is in progress".<br />

If the PARTITION; command option is executed on a terminal that is not using<br />

PowerClient, the command option is ignored.<br />

BYE;<br />

Including the BYE; command option signs you off from the originating system.<br />

You can perform a RECALL; (BYE) command to log off from your <strong>LINC</strong> System even if you<br />

have a Report running. If the Report attempts to access the terminal from which you<br />

logged off, it will terminate abnormally.<br />

For an MCP based <strong>LINC</strong> System:<br />

$ If you sign back onto the original system, an ?OPEN notification is sent, and the Fireup<br />

Ispec is displayed.<br />

$ If you switch back to the system with data, the data you send with the SWITCH.TO;<br />

command overrides the ?OPEN notification.<br />

For an OS 2200 based <strong>LINC</strong> System, if the BYE; command option is not specified, the<br />

current Ispec is retained in the STN (station id) file. If you sign back on to, or switch to the<br />

original system by using the SWITCH.TO; command, the original Ispec is displayed.<br />

ForaUNIX<strong>LINC</strong>System:<br />

$ If BYE; is not included, you remain signed on to original system as well as the target<br />

system.<br />

$ If you are running a Report (initiated by using the <strong>LINC</strong> System command :RUN or the<br />

<strong>LINC</strong> logic command RUN;) with device type of VD, a SWITCH.TO; command with the<br />

BYE; command option causes an error. You must first terminate the Report.<br />

1-252 v