System Data Item Descriptions<br />

For an MCP based <strong>LINC</strong> System, the value of GLB.INITSTN is a reference station name.<br />

The full station name corresponding to the reference station held in GLB.INITSTN is<br />

contained in the System Data item GLB.INITFULLSTN. See your MCP Based <strong>LINC</strong><br />

Administration and Operations Guide for further details.<br />

In LDA, GLB.INITSTN is initialized with the user or computer name before a session is<br />

opened. It can then be set to BATCH using the -c parameter with <strong>LINC</strong>RPT.<br />

LENGTH = 17 EDIT = A<br />

GLB.INPUTDATA<br />

GLB.INQ<br />

Note: This System Data item is valid only in Ispec logic for MCP based target hosts.<br />

GLB.INPUTDATA is a read-only System Data item which contains the data received for<br />

processing the current transaction (that is, all screen data items excluding Usage Input<br />

data items).<br />

In a Copy.From Ispec, GLB.INPUTDATA should only be accessed on the first copy (when<br />

GLB.COPY is equal to 1).<br />

LENGTH = 1920 EDIT = A<br />

GLB.INQ is a read-only System Data item. It should be used in place of the literal INQ, to<br />

allow for translation of MAINT values in multiple-language systems.<br />

For more details, see the MAINT System Data item, later in this section.<br />

GLB.LANGUAGE<br />

The System Data item GLB.LANGUAGE can be used to change the working language of a<br />

station in a multiple language environment. Its value can be changed in Ispec and Report<br />

logic.<br />

In Ispecs, if you attempt to set GLB.LANGUAGE to a language name that is not defined for<br />

the <strong>LINC</strong> System, then GLB.LANGUAGE will contain ***** until the next transaction. You<br />

should test the result of GLB.LANGUAGE immediately after any move to it in your Ispec<br />

logic.<br />

For Ispecs, the language currently in use on the station is held in the System Data item<br />

GLB.STALANG.<br />

GLB.LANGUAGE is not implemented in LDA Run Time.<br />