This form indicates that the list box applies to users of all Ispecs.<br />

data name<br />

SENDLIST.STATIC (SLSTA)<br />

A data item or literal containing the name of the list box file to be downloaded.<br />

pack<br />

Examples<br />

<strong>Reference</strong>s<br />

For MCP based <strong>LINC</strong> Systems, a data item or literal containing the pack on which the file is<br />

stored. The default is the Dictionary pack for the <strong>LINC</strong> System.<br />

extract file<br />

A literal value (A through Z), indicating an Extract file whose existing definition is to be<br />

used. The Extract file must have been defined by a DETERMINE; ACTUAL or EXTRACT;<br />

command with a RETAIN.AS; command option, or referenced by a SET.TITLE; command<br />

in the Report.<br />

In the following example, an Extract file is created and downloaded.<br />

<br />

<br />

<br />

<br />

In the next example, an Ispec CUST has the following data items:<br />

<br />

<br />

In logic, a static listbox for BRANCH is to be downloaded to PowerClient from the file<br />

BRANCHLBX, and a list box for CUSTYP is to be downloaded from the file CUSTYPLBX.<br />

The BRANCH list box is used by other Ispecs, but the CUSTYP list box is specific to CUST.<br />

<br />

<br />

"LISTBOX (LBX)" in your <strong>LINC</strong> Generate <strong>Reference</strong> <strong>Manual</strong>: Painter and Editor.<br />

‘‘SENDLIST.DYNAMIC (SLDYN)’’.<br />

The Designer Workbench Operations Guide.<br />

v 1-223