System Data Item Descriptions<br />

A value of zero means that the <strong>LINC</strong> System will continue to wait until a reply is received.<br />

(For MCP based <strong>LINC</strong> Systems, a value of zero defaults to 120 seconds.)<br />

GLB.HUBTIMEOUT is set to 300 seconds after each Automatic Entry.<br />

Note: GLB.HUBTIMEOUT is not used with External Automatic Entries to NOF or the<br />

<strong>LINC</strong> USER interface program. It is not implemented in LDA Run Time.<br />

For more information about what happens when the time set in GLB.HUBTIMEOUT is<br />

exceeded, see ‘‘AUTO; WRITE and AUTO; WRITE&CLEAR’’ in this manual.<br />

LENGTH = 6 EDIT = N<br />

GLB.INITFULLSTN<br />

GLB.INITSTN<br />

GLB.INITFULLSTN is a read-only System data item that applies to MCP based <strong>LINC</strong><br />

System Reports. For UNIX and OS 2200 based <strong>LINC</strong> Systems, the value of<br />

GLB.INITFULLSTN is the same as GLB.INITSTN.<br />

For an MCP based <strong>LINC</strong> System, the value of GLB.INITFULLSTN is the full station name of<br />

the station from which the Report was initiated.<br />

See your MCP Based <strong>LINC</strong> Administration and Operations Guide for details of full<br />

station names and reference station names.<br />

LENGTH = 251 EDIT = A<br />

GLB.INITSTN is a read-only System data item that can be accessed in Report logic to<br />

identify the terminal or username from which the Report was initiated.<br />

The value of GLB.INITSTN is BATCH if the Report was initiated:<br />

$ Through <strong>LINC</strong>/RIP for an MCP based <strong>LINC</strong> System<br />

$ In standalone mode for an MCP based <strong>LINC</strong> System<br />

$ From Startup logic for an MCP based <strong>LINC</strong> System<br />

$ Through a batch runstream for an OS 2200 based <strong>LINC</strong> System<br />

$ Through the shell for a UNIX <strong>LINC</strong> System<br />

$ Through <strong>LINC</strong>RPT with the command line option of -c for LDA<br />

$ As a Coroutine<br />

See the CALL; command in this manual for details of Coroutines.<br />

2-32 v