<strong>CE10WIN</strong>_<strong>EN</strong>_SP3<br />

Set Location<br />

ADAPT00386919 Patch ID: 37015128<br />

Description:<br />

When a report is saved in Crystal Reports or the RDC after the table location has been changed, an extra query is sent to the Oracle<br />

(native) database.<br />

New Behavior:<br />

This problem is resolved.<br />

Support 8.5 DLL<br />

ADAPT00372144 Patch ID: 36976428<br />

Description:<br />

When users export reports to Excel from the RDC, the application terminates. This problem occurs after users install the Excel<br />

Compatibility Patch.<br />

New Behavior:<br />

This problem is resolved.<br />

Templates<br />

ADAPT00388874 Patch ID: 37088822<br />

Description:<br />

In the Info Version 7 pre-maintenance release (7.0.x.192), a null running total field displays a zero value rather than a null value, and<br />

users have no option to change nulls to 0.<br />

This problem was fixed in Info 7 Maintenance Release 1 (7.0.x.15). When users migrate report instances to Crystal Enterprise 10, and<br />

those report instances were created in versions earlier than pre maintenance release (7.0.x.192), null running total fields appear as<br />

nulls rather than 0.<br />

New Behavior:<br />

A registry key has been added to provide the option to change nulls to 0 at view time.<br />

Known Limitations:<br />

A DWORD value must be created in HKEY_CURR<strong>EN</strong>T_USER/SOFTWARE/CRYSTAL DECISIONS/Crystal<br />

Reports/DatabaseOptions/OverrideConvertDatabaseNullsToDefault and HKEY_CURR<strong>EN</strong>T_USER/SOFTWARE/CRYSTAL<br />

DECISIONS/Crystal Reports/DatabaseOptions/OverrideConvertOtherNullsToDefault. A value of 1 sets the value to true.<br />

A value of -1 sets the value to false. Any value outside of 1 or -1 is invalid; the flag remains set to the previous valid value.<br />

This HotFix is only for reports that are based on dictionaries and queries. The DatabaseOptions registry keys must be set for the<br />

account under which the service that loads the report is run, or under HKEY_CURR<strong>EN</strong>T_USER.