<strong>CE10WIN</strong>_<strong>EN</strong>_SP1<br />
System configuration<br />
ADAPT00260900 Patch ID: 36013705<br />
Description:<br />
When two or more Event Servers are busy and one of them is stopped, the other Event Servers fail to process their own reports and ru<br />
their jobs.<br />
On the transport layer, only one listener object (the FAT listener object) registers with each Event Server. When an Event Server shuts<br />
down, it performs a disconnect method.<br />
The disconnect method prevents the listener from receiving future event notifications-- for all Event servers. This affects Event Servers<br />
that are still running.<br />
New Behavior:<br />
The component has been fixed so that when more than one Event Server is busy, the disconnect method will not trigger when an Even<br />
Server is stopped.<br />
Usability<br />
ADAPT00049226 Patch ID: 36010853<br />
Description:<br />
When using Windows NT 4.0 to view reports that use the ActiveX Viewer, once the viewer has been downloaded, the following error<br />
appears: "The ActiveX Viewer is unable to create its resource objects."<br />
New Behavior:<br />
This problem is resolved.<br />
User management<br />
ADAPT00188226 Patch ID: 35524063<br />
Description:<br />
When a user logs on to the Crystal Enterprise environment using Windows Active Directory authentication, the logon fails when the<br />
Active Directory user belongs to many Active Directory groups.<br />
New Behavior:<br />
This occurred when the token returned to Crystal Enterprise from Active Directory was greater than 4k in size. A change has been<br />
made to allow a larger token to be received, therefore allowing the logon to succeed.<br />
Visual Linking<br />
ADAPT00265936 Patch ID: 36072499<br />
Description:<br />
When two tables are linked to one another, the error message "The table does not exist in the document" appears, if one<br />
or both of the table names contain an underscore.<br />
The cause of the problem is that the alias for the table name fails to be returned.<br />
New Behavior:<br />