<strong>CE10WIN</strong>_<strong>EN</strong>_SP1<br />

Platform .NET SDK<br />

ADAPT00273670 Patch ID: 36163993<br />

Description:<br />

When a backslash character ("\") in a parameter is appended to a URL, the backslash is lost when a user attempt to print through the<br />

ActiveX Print Control. Then, the following error appears: "Crystal Print Control. A communication error occurred. Printing will be<br />

stopped."<br />

The cause of the problem is that the query string is not encoded and, as a result, the backslashes are truncated.<br />

New Behavior:<br />

The URL is properly encoded. This problem is resolved.<br />

Platform COM SDK<br />

ADAPT00258928 Patch ID: 36002145<br />

Description:<br />

In Crystal Enterprise 10, objects that are marked as SI_HIDD<strong>EN</strong>_OBJECT in the APS cannot be returned when queried.<br />

The cause of the problem is that the SI_HIDD<strong>EN</strong>_OBJECT!=1 constraint is always appended to the function that generates the implicit<br />

constraints. To have objects returned when queried, the InfoStore should ensure that the constraint is removed.<br />

New Behavior:<br />

The InfoStore only adds this constraint when the SI_HIDD<strong>EN</strong>_OBJECT property is not explicitly specified in the query.<br />

Portal<br />

ADAPT00229571 Patch ID: 36093782<br />

Description:<br />

If Crystal Enterprise WCS and Windows IIS are configured to use Windows NT authentication for single sign-on, and the Crystal<br />

Enterprise ActiveX viewer is used to save Crystal Analysis reports to Crystal Enterprise, an error is thrown. As a result, the view is not<br />

saved.<br />

The cause of the problem is that the NT authentication logon token expires every 2 minutes. When the Crystal Enterprise session has<br />

been inactive longer than this time, saving the CAP view through the ActiveX Viewer causes the error. That is, the request that is sent<br />

through the WCS, to save the view a second time, is malformed; the malformed request causes the error. (The request is only made aft<br />

the token expires.)<br />

New Behavior:<br />

To prevent the request from being malformed, the request sent through the WCS to save the view a second time is no longer recreated<br />

Instead, the request replaces the Windows NT credentials from the first request and sends it again.<br />

Portal Launchpad/Sample/Tools<br />

ADAPT00219874 Patch ID: 36163217<br />

Description:<br />

The link to "Preferences Manager" in the Crystal Launchpad is broken.<br />

New Behavior:<br />