CE10WIN_EN_SP6
CE10WIN_EN_SP6
CE10WIN_EN_SP6
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>CE10WIN</strong>_<strong>EN</strong>_SP2<br />
Portal<br />
ADAPT00265696 Patch ID: 36069452<br />
Description:<br />
When two or more Crystal Management Servers are clustered and Tomcat is used as the web server, "@clustername" fails when it is<br />
specified for the CMC property. An error message states that the "@clustername" is unavailable.<br />
The Java components do not support cluster names that begin with the "@" character.<br />
New Behavior:<br />
This problem is resolved.<br />
Known Limitations:<br />
If default port number 6400 is not used for the CMS, an initial logon with "@clustername" will not proceed. Using "@clustername"<br />
requires a successful initial logon to the CMS.<br />
Portal Launchpad/Sample/Tools<br />
ADAPT00268258 Patch ID: 36119069<br />
Description:<br />
In Crystal Enterprise 10, Discussions does not function correctly when Single Sign-On is enabled. When users attempt to create a new<br />
discussion, the browser hangs indefinitely.<br />
New Behavior:<br />
This problem is resolved.<br />
Processing extensions<br />
ADAPT00284777 Patch ID: 36265316<br />
Description:<br />
In Crystal Enterprise 10, Default Parameter Values are duplicated after a Processing Extension is added to a report.<br />
New Behavior:<br />
This problem is resolved.<br />
Push Down<br />
ADAPT00285620 Patch ID: 36208049<br />
Description:<br />
When Max and Min summary operations are performed in a group against BinInt and Decimal type fields, their values are divided by<br />
a factor of 100.<br />
The cause of the problem is that the sign value is accessed, rather than the scale value, on large endian platforms.<br />
New Behavior:<br />
This problem is resolved.<br />
Query Builder