INTERIORS - GENERAL<br />
50. Is the diameter of the handrail between 30mm and 50mm? <br />
(AS1428.1 – Clause 12(b)<br />
51 Is the top 270 o arc free along the full length of the handrail <br />
With no obstruction within 15mm?<br />
(AS1428.1 – Clause 12(b)<br />
52 Do the handrails extend a minimum of 300mm past the <br />
edge of the ramp transition and return back on itself for<br />
180 degrees, away to the side wall or turned<br />
downwards to the floor? (AS1428.1 – figures. 26(C) & 26(D)<br />
& Clause 12(g)<br />
53 If ramp is curved does it have a minimum width of <br />
1500mm at the curve?<br />
(AS1428.1 – figure 20 & Clause 10.4(d)<br />
54 Is the ramp surface slip resistant? <br />
(AS1428.1 – Clause 7.1<br />
55 Are there tactile ground indicators at the top and bottom <br />
of the ramp and on the landings, set back 300mm from the<br />
edge of the transition points at the top and bottom of the<br />
ramp? (AS1428.4.1 – Clause 2.3.3(c))<br />
56 Do the Tactile Ground Surface Indicators extend across <br />
the full width of the landings?<br />
(AS1428.4.1 – Clause 2.2.3.(a))<br />
57 Do the Tactile Ground Surface Indicators have the minimum <br />
luminance contrast of .3 or 30%compared to the surrounding<br />
surface? (AS1428.4.1 – Clause 2.2(b))<br />
58 If discrete or composite TGSI’s are used do they meet <br />
the required Higher luminance contrast levels of 45% or<br />
60% respectively? (AS1428.4.1 – Clause 2.2(b)(ii) & (iii).<br />
59 Do the Tactile Ground Surface Indicators<br />
have a minimum of 12 truncated cones<br />
<br />
in depth when being approached from an open area and<br />
a minimum of 6 truncated cones in depth when<br />
being approached from an enclosed area?<br />
(AS1428.1 – Clause 10.3 (f) Fig 16 & 17) & AS1428.4.1 Clause 2.3.3 (e) & (f)<br />
Buildings and Facilities Checklist – Towards Best Practice (Aust Standards updated<br />
February 2011) 3.32