LIFTS<br />

Facility: ____________________________________________________________<br />

Date: ____________________________________________________________<br />

Assessor: ____________________________________________________________<br />

Relevant access requirements:<br />

♦ HRAC (HREOC)Advisory Notes on <strong>Access</strong> to Premises (Updated Feb 1999)<br />

Clauses: 5.7, 5.13 & 5.14.<br />

♦ AS1428.1 - 2009 - Design for access and mobility – New Building Work.<br />

♦ AS1428.2 - 1992 - Design for access and mobility – Building and Facilities<br />

(in part only as the majority of this standard has been merged with<br />

AS1428.1 – 2009, the remaining sections still apply on fixtures fittings and<br />

fitments.)<br />

♦ AS1735.12 - 1999 - Lifts, escalators and moving walks.<br />

Important points to consider:<br />

♦<br />

♦<br />

lifts are essential for people with disabilities to have access to all levels of the<br />

facility. Consideration needs to be given to door width, lift size and control button<br />

style and height; and<br />

for people with sensory disabilities (hearing and vision impairment), auditory,<br />

tactile and visual considerations are important (eg. luminance contrast, glare and<br />

font size and type of controls/instructions).<br />

Lifts<br />

Legend:<br />

YES NO <br />

INSERT BUILDING LEVELS<br />

<br />

1. Is there a lift available to all floors? <br />

(AS1428.2 – Clause 12)<br />

2. Is it clearly sign posted from the entrance area? <br />

3. Is each floor level clearly signed (visual and tactile) <br />

on lift entrance frame? (AS1735.12 – Appendix 8.5(a))<br />

4. Are the external control buttons at a height of <br />

900mm-1200mm? (AS1735.12 - Clause 7.3.1)<br />

5. Is the lift door width a minimum of 900mm clear <br />

opening? (AS1735.12 - Clause 2.2)<br />

YES NO<br />

6. Travel ≤ 12 m except a platform lift, is the floor area<br />

≥ 1100mm wide X 1400mm depth.<br />

Buildings and Facilities Checklist – Towards Best Practice (Aust Standards updated<br />

February 2011) 3.36