Access Resource Kit (ARK) - Disability Services Commission
Access Resource Kit (ARK) - Disability Services Commission
Access Resource Kit (ARK) - Disability Services Commission
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
TOILETS<br />
contrast to the background?<br />
14. If the door opens inwards is the circulation space large <br />
Enough so that a person in a wheelchair can shut the<br />
door once inside?<br />
15. Is there a 1400mm space in front of the pan? <br />
(100mm of the 1200mm is allowed under the basin)<br />
(This allows front transfers from a wheelchair)<br />
(AS1428.1-Figure 43)<br />
16. Is there 1250mm at one side of the pan? <br />
(This allows side transfers from a wheelchair)<br />
(AS1428.1 - Figure 43)<br />
17. Is the seat height between 460mm-480mm? <br />
(AS1428.1 - Figure 41)<br />
18. Is the front of the pan 800+/-10mm from the rear wall? <br />
(AS1428.1 - Figure 39)<br />
19. Is there a grab-rail next to the toilet at 800mm- <br />
810mm high? (AS1428.1-Clause 15.2.7<br />
Figure 42)<br />
20. Is there a rail behind the toilet at 800mm-810mm <br />
high?(this allows side transfers and sitting on toilet)<br />
(AS1428.1 – Clause 15.2.7 Figure 42(b)<br />
21. Can the toilet paper be easily reached? (forward <br />
of the pan and 700mm maximum height)<br />
(AS1428.1 – clause 15.2.6 & Figure 41)<br />
22. Is the flushing control within easy reach and <br />
easy to operate? (maximum height 1100mm)<br />
(AS1428.1 – Clause 15.2.5 & Figure 40)<br />
23 Is there a basin in the toilet cubicle and outside<br />
the required pan circulation area?<br />
(AS1428.1 - Clause 15.3.1 & figure 43.)<br />
<br />
24. Is the basin located not closer than 1400mm to <br />
the pan? (AS1428.1 - Figure 43)<br />
25. Is there sufficient toe plate and leg room under <br />
the basin? (AS1428.1 Figures 44(A) & 44(B))<br />
26. Does the basin have knee-space underneath? <br />
(AS1428.1 – Figures 44(A) & 44(B))<br />
27. Are the tap handles lever, sensor type or similar? <br />
Buildings and Facilities Checklist – Towards Best Practice (Aust Standards updated<br />
February 2011) 3.40