2. Freshbrew & Espresso Machines: <strong>Evolution</strong> machines fitted with a paperless<br />
freshbrew brewer or CoEx® brewer must be connected to the water supply via<br />
a water filter. This filter must be of food grade quality and able to remove<br />
temporary hardness (scale), heavy metals (lead, copper, iron, cadmium), chlorine<br />
and any organic pollutant’s/discolouration. Crane Merchandising<br />
Systems recommend and supply the Brita AquaQuell water<br />
filter.<br />
Warning! If the machines indicated above are connected to the water supply<br />
and used without a water filter as specified, the warranty will be void.<br />
3. Connect the flexi-hose supplied with the machine to the stopcock ensuring that<br />
the seal supplied is fitted correctly. Flush the system (several gallons) before<br />
connecting the machine.<br />
3. Connect the hose to the inlet valve located on the rear of the machine. Ensure<br />
that the seal is correctly fitted. Ensure that all water supply fittings are tight.<br />
4. Turn on the water supply at the stop tap and check for leaks. Prime the water<br />
filter (where fitted) following the instructions supplied by the filter manufacturer.<br />
2.3 Connecting the Electrical Supply<br />
Safety First! The machine must be earthed. On no account should it be<br />
earthed only to the water supply pipe.<br />
The machine must be connected to a 230 Volt 50Hz 13 amp fused switched socket<br />
outlet, installed to the latest edition of the IEE regulations, using a 3 pin BS approved<br />
13 amp fused plug.<br />
Important: If the mains lead becomes damaged in any way it must be replaced by a<br />
special lead available from the manufacturer.<br />
2.4 Commissioning Procedure<br />
<strong>Technical</strong> <strong>Manual</strong><br />
The following procedure must be carried out by a trained installation engineer before<br />
the machine can be used for the first time. Ensure that the electrical and water services<br />
to the machine are connected correctly. Check for leaks in the water supply.<br />
1. Open the front door of the machine. Fit the door switch bracket to the door using<br />
the two screws provided. Ensure that the bracket will operate the door switch<br />
when the door is closed. Switch on the electricity supply.<br />
2. Ensure that the waste bucket is fitted correctly. Clip the level detector and<br />
overflow pipes correctly onto the rim of the bucket.<br />