2. Freshbrew & Espresso Machines: <strong>Evolution</strong> machines fitted with a paperless<br />

freshbrew brewer or CoEx® brewer must be connected to the water supply via<br />

a water filter. This filter must be of food grade quality and able to remove<br />

temporary hardness (scale), heavy metals (lead, copper, iron, cadmium), chlorine<br />

and any organic pollutant’s/discolouration. Crane Merchandising<br />

Systems recommend and supply the Brita AquaQuell water<br />

filter.<br />

Warning! If the machines indicated above are connected to the water supply<br />

and used without a water filter as specified, the warranty will be void.<br />

3. Connect the flexi-hose supplied with the machine to the stopcock ensuring that<br />

the seal supplied is fitted correctly. Flush the system (several gallons) before<br />

connecting the machine.<br />

3. Connect the hose to the inlet valve located on the rear of the machine. Ensure<br />

that the seal is correctly fitted. Ensure that all water supply fittings are tight.<br />

4. Turn on the water supply at the stop tap and check for leaks. Prime the water<br />

filter (where fitted) following the instructions supplied by the filter manufacturer.<br />

2.3 Connecting the Electrical Supply<br />

Safety First! The machine must be earthed. On no account should it be<br />

earthed only to the water supply pipe.<br />

The machine must be connected to a 230 Volt 50Hz 13 amp fused switched socket<br />

outlet, installed to the latest edition of the IEE regulations, using a 3 pin BS approved<br />

13 amp fused plug.<br />

Important: If the mains lead becomes damaged in any way it must be replaced by a<br />

special lead available from the manufacturer.<br />

2.4 Commissioning Procedure<br />

<strong>Technical</strong> <strong>Manual</strong><br />

The following procedure must be carried out by a trained installation engineer before<br />

the machine can be used for the first time. Ensure that the electrical and water services<br />

to the machine are connected correctly. Check for leaks in the water supply.<br />

1. Open the front door of the machine. Fit the door switch bracket to the door using<br />

the two screws provided. Ensure that the bracket will operate the door switch<br />

when the door is closed. Switch on the electricity supply.<br />

2. Ensure that the waste bucket is fitted correctly. Clip the level detector and<br />