<strong>Technical</strong> <strong>Manual</strong><br />
Error Diagnostics Fault<br />
Message Screen Text Description<br />
Temporarily Card reader reports Repeatable error with card reader, but<br />
Out Of Service a comm error card reader in service. Unable to<br />
communicate with card reader<br />
Temporarily Card reader error Problem with card reader.<br />
Out Of Service<br />
Manufacturing error detected<br />
Temporarily Card reader failed Card reader is out of service<br />
Out Of Service<br />
OOS err<br />
Temporarily Card reader reports Comm error with card reader.<br />
Out Of Service comm error & is OOS Out of service<br />
Temporarily Card jammed in Card jam<br />
Out Of Service<br />
card reader<br />
Temporarily Card reader failure Problem with card reader.<br />
Out Of Service<br />
Manufacturing error detected<br />
Temporarily Card reader Card reader needs servicing<br />
Out Of Service<br />
requests servicing<br />
An Error Has - Low water during a CoEx®<br />
occurred<br />
brewer clean<br />
Sorry Out Of Service No Water No Water Available<br />
No Water Available Available (B2C Machines Only)<br />
10.2 Heater Tank De-Scale Procedure<br />
To maintain correct water levels and water temperature the heater tank must be<br />
inspected regularly and, if necessary, be de-scaled. To ensure long and trouble-free<br />
operation, Crane Merchandising Systems recommend that all machines have a water<br />
filter fitted. We recommend and supply the Brita AquaQuell Compact water filter.<br />
There are a number of ways of de-scaling the heater tank. The tank can be removed<br />
and scraped out with a blunt tool but it can also be left inside the machine and a descaling<br />
agent introduced into the tank. This eliminates the need to remove the<br />
thermistor, water level probe and all the outlet valves from the tank, saving time and<br />
money. Always remember to fit a new water filter and boiler seal after de-scaling.<br />
Use the following steps as a guideline only and always refer to the instructions supplied<br />
with the de-scaling agents regarding dosage and de-scaling time.<br />
1. Switch off the machine and open the door. Remove all canisters and back covers.<br />
2. Using the drain hose fitted to the tank, remove the bung and drain the water from<br />
the heater into a suitable water tight container.<br />
94<br />
Safety First! Allow the water in the tank to cool before draining.