<strong>Technical</strong> <strong>Manual</strong><br />

Error Diagnostics Fault<br />

Message Screen Text Description<br />

Temporarily Card reader reports Repeatable error with card reader, but<br />

Out Of Service a comm error card reader in service. Unable to<br />

communicate with card reader<br />

Temporarily Card reader error Problem with card reader.<br />

Out Of Service<br />

Manufacturing error detected<br />

Temporarily Card reader failed Card reader is out of service<br />

Out Of Service<br />

OOS err<br />

Temporarily Card reader reports Comm error with card reader.<br />

Out Of Service comm error & is OOS Out of service<br />

Temporarily Card jammed in Card jam<br />

Out Of Service<br />

card reader<br />

Temporarily Card reader failure Problem with card reader.<br />

Out Of Service<br />

Manufacturing error detected<br />

Temporarily Card reader Card reader needs servicing<br />

Out Of Service<br />

requests servicing<br />

An Error Has - Low water during a CoEx®<br />

occurred<br />

brewer clean<br />

Sorry Out Of Service No Water No Water Available<br />

No Water Available Available (B2C Machines Only)<br />

10.2 Heater Tank De-Scale Procedure<br />

To maintain correct water levels and water temperature the heater tank must be<br />

inspected regularly and, if necessary, be de-scaled. To ensure long and trouble-free<br />

operation, Crane Merchandising Systems recommend that all machines have a water<br />

filter fitted. We recommend and supply the Brita AquaQuell Compact water filter.<br />

There are a number of ways of de-scaling the heater tank. The tank can be removed<br />

and scraped out with a blunt tool but it can also be left inside the machine and a descaling<br />

agent introduced into the tank. This eliminates the need to remove the<br />

thermistor, water level probe and all the outlet valves from the tank, saving time and<br />

money. Always remember to fit a new water filter and boiler seal after de-scaling.<br />

Use the following steps as a guideline only and always refer to the instructions supplied<br />

with the de-scaling agents regarding dosage and de-scaling time.<br />

1. Switch off the machine and open the door. Remove all canisters and back covers.<br />

2. Using the drain hose fitted to the tank, remove the bung and drain the water from<br />

the heater into a suitable water tight container.<br />

94<br />

Safety First! Allow the water in the tank to cool before draining.