<strong>Technical</strong> <strong>Manual</strong><br />
Error Diagnostics Fault<br />
Message Screen Text Description<br />
Sorry Out of Service No cup delivered ring 1 Problem with CDU (cup jam)<br />
Please Insert Mug SureVend on/SureVend No more cups being dispensed<br />
error and must SureVend<br />
Sorry Out of Service Low water Low water level in heater tank<br />
Low Water<br />
Sorry Out of Service Water tank Water in the heater tank is below the<br />
Water Tank Heating heating minimum vend temperature<br />
Sorry Out of Service Fill timeout/ low water Machine has been filling for 2 minutes and<br />
Fill Timeout<br />
not reached optimum level<br />
Sorry Out of Service Invalid temp 1. Comms error between I/O & MPU<br />
Invalid Temp<br />
2. Machine has exceeded optimum<br />
boiler temp<br />
3. Temperature probe fault<br />
Sorry Out of Service Brewer jam Brewer has not moved from its home<br />
Brewer Jam<br />
position and may be jammed<br />
Sorry Out of Service Brewer not homed Brewer has not returned to its home<br />
Brewer Not Homed<br />
position and may be jammed<br />
Sorry Out of Service Coin mech Communication error detected between<br />
No Monetary Device comm monetary device and machine<br />
Sorry Out of Service No monetary Machine is configured for an incorrect<br />
No Monetary Device device-fatal/No monetary device, or the device<br />
monetary device<br />
is not responding<br />
Temporarily Coin mech ROM MDB coin mech ROM checksum<br />
Out Of Service<br />
test failed (fatal error)<br />
Temporarily Coin mech accept MDB coin mech is<br />
Out Of Service unplugged unplugged or faulty<br />
Temporarily Coin mech accept Coin jam detected in coin acceptor<br />
Out Of Service<br />
jam<br />
Temporarily Coin mech Coin jam detected in coin tube<br />
Out Of Service<br />
payout jam<br />
Temporarily Coin mech Coin tube sensor fault detected<br />
Out Of Service<br />
tube sensor<br />
Temporarily Coin mech all No useable coin tubes. Machine<br />
Out Of Service tubes err unable to pay out<br />
Temporarily Coin mech Problem with coin tube. Tube indicates<br />
Out Of Service tube err full, but coin count is zero<br />
Temporarily Card reader comm Fatal error. Cannot communicate<br />
Out Of Service<br />
with the card reader<br />
Temporarily Single card reader Transient error with card reader, but card<br />
Out Of Service error reader in service. Unable to communicate<br />
with the card reader<br />