<strong>Technical</strong> <strong>Manual</strong><br />

Section 10 - Diagnostics and Maintenance Procedures<br />

10.1Diagnostics<br />

The following pages list the error messages that may be displayed, diagnostics messages<br />

accessed via the engineers program and fault descriptions. For further help and advice<br />

please contact the Crane Merchandising Systems <strong>Technical</strong> Support Helpline on 01249<br />

667323.<br />

Error Diagnostics Fault<br />

Message Screen Text Description<br />

Sorry Out of Service Head not homed Dispense head has not returned to<br />

Head Not Homed<br />

home position in expected time<br />

Sorry Out of Service Head not extended Dispense head has not fully<br />

Head Not Extended<br />

extended in the expected time<br />

Sorry Out of Service Waste bucket full Waste bucket full<br />

Waste Bucket Full<br />

Temporarily Init failed restart Machine failed on initialisation<br />

Out of Service<br />

Sorry Out of Service No I/O comm Comms error detected between<br />

No I/O Comm<br />

mpu and I/O board<br />

Initialising - CoEx® brewer not situated<br />

correctly in the machine<br />

Temporarily All selections All drink selections have been disabled<br />

Out Of Service<br />

disabled<br />

Sorry Out of Service Rinsing Automatic or manual rinse<br />

Rinsing<br />

cycle in progress<br />

- Rinsing A rinsing cycle was interrupted<br />

and not completed<br />

Out Of Cups Cup turret/no cups/ Unable to find cup stack.<br />

Please Insert Mug no cups Cup turret has timed-out on initialisation<br />

Sorry Out of Service No cups and mug Machine is out of cups and<br />

No Cups sensor failure mug sensor is faulty<br />

Out Of Cups No cups/no cups No cups are available but the mug<br />

Please Insert Mug<br />

sensor is working<br />

Out Of Cups No cup delivered ring 1 Non fatal error detected with<br />

Please Insert Mug SV on SureVend cup mechanism<br />

Please Remove Cup Mug sensor error/ An error has occurred with the SureVend<br />

please remove cup<br />

sensor during a vend<br />

Sorry Out of Service SureVend error and No cups remaining and fault<br />

Mug Sensor Error must SureVend with mug sensor<br />

Please Remove Cup Mug sensor error Cup not removed from dispense<br />

area after vend completed<br />

or faulty mug sensor<br />