136 Assess Measurement Systems Chapter 8<br />

Additional Example of Measurement Systems Analysis<br />

Just to be sure, you decide to look at the Bias Comparison chart, which indicates whether an operator is<br />

measuring parts too high or too low. From the red triangle menu next to Measurement Systems Analysis,<br />

select Bias Comparison.<br />

Figure 8.10 Bias Comparison<br />

Looking at the Bias Comparison chart, you make the following observations:<br />

• Operator A <strong>and</strong> Operator B have detectable measurement bias, as they are significantly different from<br />

the overall average.<br />

• Operator A is significantly biased low.<br />

• Operator B is significantly biased high.<br />

• Operator C is not significantly different from the overall average.<br />

Classify Your Measurement System<br />

Examine the EMP Results report to classify your measurement system <strong>and</strong> look for opportunities for<br />

improvement. From the red triangle menu next to Measurement Systems Analysis, select EMP Results.