31.03.2014 Views

Grundfos E-pumps

Grundfos E-pumps

Grundfos E-pumps

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Grundfos</strong> E-<strong>pumps</strong><br />

1<br />

1. Introduction to E-<strong>pumps</strong><br />

General introduction<br />

This product guide deals with <strong>Grundfos</strong> <strong>pumps</strong> fitted<br />

with <strong>Grundfos</strong> MLE motors, 1/2 to 30 Hp<br />

(0.37 - 22 kW). These motors are standard<br />

asynchronous motors with integrated variable<br />

frequency drive (VFD) and controller. In some cases,<br />

the <strong>pumps</strong> have a factory-fitted sensor.<br />

These <strong>pumps</strong> are referred to as E-<strong>pumps</strong>.<br />

For information about E-<strong>pumps</strong> with a higher shaft<br />

power output, see our CUE range of VFDs,<br />

30 to 300 Hp (22-250 kW).<br />

In new installations, the E-<strong>pumps</strong> provide a number of<br />

advantages. The integrated variable frequency drive<br />

has a built-in motor protection function which protects<br />

both motor and electronics against overload. This<br />

means that E-pump installations do not require a motor<br />

starter, but only a normal short-circuit protection for the<br />

cable.<br />

Setpoint<br />

PI<br />

controller Controller<br />

Introduction to E-<strong>pumps</strong><br />

Variable Freq.<br />

frequency<br />

conv.<br />

drive<br />

M<br />

Fig. 2<br />

Components of a <strong>Grundfos</strong> E-pump<br />

TM05 2979 0812<br />

TM03 0431 5104<br />

Fig. 1<br />

<strong>Grundfos</strong> E-<strong>pumps</strong><br />

An E-pump is not just a pump, but a system which is<br />

able to solve application problems or save energy in<br />

a variety of pump installations. All that is required, is<br />

the power supply connection and the fitting of the<br />

E-pump in the pipe system, and the pump is ready for<br />

operation.<br />

The pump has been tested and pre-configured from<br />

the factory. The operator only has to specify the<br />

desired setpoint (pressure) and the system is<br />

operational.<br />