8<br />
<strong>Grundfos</strong> E-<strong>pumps</strong><br />
Bus communication<br />
CIM 250 GSM/GPRS module<br />
Fig. 68 CIM 250 GSM/GPRS module<br />
The CIM 250 GSM/GPRS module (CIM = Communication<br />
Interface Module) enables data transmission<br />
between a GSM/GPRS network and a <strong>Grundfos</strong><br />
E-pump.<br />
The CIM 250 is fitted in the E-pump to be<br />
communicated with or in a CIU unit.<br />
The CIM 250 can communicate the following data<br />
points between the E-pump and a management<br />
system.<br />
Data points<br />
CIM 250<br />
Multistage E-<strong>pumps</strong><br />
with or without sensor<br />
15 - 30 Hp<br />
From management system (SCADA) to E-pump<br />
Control mode ● 2)<br />
Setpoint, 0-100 %<br />
Start/stop<br />
Max.<br />
Min.<br />
From E-pump to management system (SCADA)<br />
Fault indication<br />
●<br />
Operating indication<br />
●<br />
Actual control mode<br />
●<br />
Actual head ● 3)<br />
Actual flow<br />
Actual power consumption<br />
●<br />
Operating hours<br />
●<br />
Energy consumption<br />
●<br />
Liquid temperature ● 3)<br />
Speed [rpm]<br />
●<br />
● Available.<br />
1)<br />
Control modes: Proportional pressure, constant pressure or<br />
constant curve.<br />
2)<br />
Control modes: Constant pressure, constant flow or constant<br />
curve, depending on connected sensor type.<br />
3) Depending on connected sensor type:<br />
If a differential-pressure sensor is connected, head is indicated in<br />
[kPa].<br />
If a flow sensor is connected, flow is indicated in [m 3 /h].<br />
If a temperature sensor is connected, liquid temperature is indicated<br />
in [°C].<br />
●<br />
●<br />
●<br />
●<br />
TM04 6260 5209<br />
CIM 300 BACnet module<br />
Fig. 69 CIM 300 BACnet module<br />
The CIM 300 BACnet module (CIM = Communication<br />
Interface Module), which is a BACnet master, enables<br />
data transmission between a BACnet MS/TP<br />
(Master-Slave/Token Passing) network and a <strong>Grundfos</strong><br />
E-pump.<br />
The CIM 300 is fitted in the E-pump to be<br />
communicated with or in a CIU unit.<br />
The CIM 300 can communicate the following data<br />
points between the E-pump and a management<br />
system.<br />
Data points<br />
CIM 300<br />
Multistage E-<strong>pumps</strong><br />
with or without sensor<br />
15 - 30 Hp<br />
From management system (SCADA) to E-pump<br />
Control mode ● 2)<br />
Setpoint, 0-100 %<br />
Start/stop<br />
Max.<br />
Min.<br />
From E-pump to management system (SCADA)<br />
Fault indication<br />
●<br />
Operating indication<br />
●<br />
Actual control mode<br />
●<br />
Actual head ● 3)<br />
Actual flow<br />
Actual power consumption<br />
●<br />
Operating hours<br />
●<br />
Energy consumption<br />
●<br />
Liquid temperature ● 3)<br />
Speed [rpm]<br />
● Available.<br />
1) Control modes: Proportional pressure, constant pressure or<br />
constant curve.<br />
2)<br />
Control modes: Constant pressure, constant flow or constant<br />
curve, depending on connected sensor type.<br />
3)<br />
Depending on connected sensor type:<br />
If a differential-pressure sensor is connected, head is indicated in<br />
[kPa].<br />
If a flow sensor is connected, flow is indicated in [m 3 /h].<br />
If a temperature sensor is connected, liquid temperature is indicated<br />
in [°C].<br />
●<br />
●<br />
●<br />
●<br />
●<br />
GrA6120<br />
60