<strong>Grundfos</strong> E-<strong>pumps</strong><br />

8<br />

CIM 150 Profibus module<br />

Fig. 66 CIM 150 Profibus module<br />

The CIM 150 Profibus module (CIM = Communication<br />

Interface Module), which is a Profibus slave, enables<br />

data transmission between a Profibus-DP network and<br />

a <strong>Grundfos</strong> E-pump.<br />

The CIM 150 is fitted in the E-pump to be<br />

communicated with or in a CIU unit.<br />

The CIM 150 can communicate the following data<br />

points between the E-pump and a management<br />

system.<br />

GrA6121<br />

CIM 200 Modbus module<br />

Fig. 67 CIM 200 Modbus module<br />

The CIM 200 Modbus module (CIM = Communication<br />

Interface Module), which is a Modbus slave, enables<br />

data transmission between a Modbus RTU network<br />

and a <strong>Grundfos</strong> E-pump.<br />

The CIM 200 is fitted in the E-pump to be<br />

communicated with or in a CIU unit.<br />

The CIM 200 can communicate the following data<br />

points between the E-pump and a management<br />

system.<br />

GrA6120<br />

Bus communication<br />

CIM 150<br />

CIM 200<br />

Data points<br />

Multistage E-<strong>pumps</strong><br />

with or without sensor<br />

15 - 30 Hp<br />

Data points<br />

Multistage E-<strong>pumps</strong><br />

with or without sensor<br />

15 - 30 Hp<br />

From management system (SCADA) to E-pump<br />

Control mode ● 2)<br />

Setpoint, 0-100 %<br />

Start/stop<br />

Max.<br />

Min.<br />

From E-pump to management system (SCADA)<br />

Fault indication<br />

●<br />

Operating indication<br />

●<br />

Actual control mode<br />

●<br />

Actual head ● 3)<br />

Actual flow<br />

Actual power consumption<br />

●<br />

Operating hours<br />

●<br />

Energy consumption<br />

●<br />

Liquid temperature ● 3)<br />

Speed [rpm]<br />

●<br />

● Available.<br />

1)<br />

Control modes: Proportional pressure, constant pressure or<br />

constant curve.<br />

2)<br />

Control modes: Constant pressure, constant flow, constant curve,<br />

depending on connected sensor type.<br />

3) Depending on connected sensor type:<br />

If a differential-pressure sensor is connected, head is indicated in<br />

[kPa].<br />

If a flow sensor is connected, flow is indicated in [m 3 /h].<br />

If a temperature sensor is connected, liquid temperature is indicated<br />

in [°C].<br />

●<br />

●<br />

●<br />

●<br />

From management system (SCADA) to E-pump<br />

Control mode ● 2)<br />

Setpoint, 0-100 %<br />

Start/stop<br />

Max.<br />

Min.<br />

From E-pump to management system (SCADA)<br />

Fault indication<br />

●<br />

Operating indication<br />

●<br />

Actual control mode<br />

●<br />

Actual head ● 3)<br />

Actual flow<br />

Actual power consumption<br />

●<br />

Operating hours<br />

●<br />

Energy consumption<br />

●<br />

Liquid temperature ● 3)<br />

Speed [rpm]<br />

●<br />

● Available.<br />

1)<br />

Control modes: Proportional pressure, constant pressure or<br />

constant curve.<br />

2)<br />

Control modes: Constant pressure, constant flow or constant<br />

curve, depending on connected sensor type.<br />

3) Depending on connected sensor type:<br />

If a differential-pressure sensor is connected, head is indicated in<br />

[kPa].<br />

If a flow sensor is connected, flow is indicated in [m 3 /h].<br />

If a temperature sensor is connected, liquid temperature is indicated<br />

in [°C].<br />