INSTALLATION<br />
13 PREPARING T<strong>HE</strong> WALL<br />
IMPORTANT.<br />
Ensure that, during the cutting operation, masonry<br />
falling outside of the building does not cause damage<br />
or personal injury.<br />
1. Cut the flue hole (preferably with a 5" <strong>co</strong>re boring<br />
tool), ensuring that the hole is square to the wall.<br />
Both wall faces immediately around the cut hole<br />
should be flat.<br />
2. Drill 3 holes with an 8mm masonry drill and<br />
insert the plastic plugs, provided, for the wall<br />
mounting plate.<br />
X<br />
Section<br />
through wall<br />
Rear flue only<br />
5" diameter hole<br />
Side flue only<br />
5" diameter hole<br />
Note. Check all of the hole<br />
positions before drilling.<br />
esp8816<br />
14 SETTING T<strong>HE</strong> FLUE - REAR Wall thicknesses of 200 to 426mm<br />
Notes.<br />
a. If using the extension ducts go to Frame 16.<br />
b. If the stand-off frame is used it is essential add 33mm to<br />
'X' the measured wall thickness when marking the flue<br />
(this will allow for the fitted frame).<br />
Drill hole<br />
Adhere sealing tape<br />
c. For wall thickness less than 200mm use none teles<strong>co</strong>pic<br />
b pack.<br />
X + 85<br />
1. Measure and note wall thickness X. Refer to Frame 10.<br />
2. Add 85mm (4") to dimension X and set teles<strong>co</strong>pic flue<br />
length as indicated in drawing.<br />
3. Using a 3.5mm drill bit, drill two holes in outer air duct<br />
taking care not to pierce plastic inner flue.<br />
4. Fix to length using self tappers provided.<br />
5. Seal out air duct using the tape provided.<br />
15 SETTING T<strong>HE</strong> FLUE - SIDE Wall thicknesses of 140 to 365mm<br />
Note.<br />
a. If using the extension ducts go to Frame 16.<br />
b. For shorter flue requirements use non teles<strong>co</strong>pic<br />
b pack.<br />
1. Measure and note wall thickness X. Refer to Frame 10.<br />
2. Measure distance from side of boiler to inside of wall<br />
and add to wall thickness X = L. Refer to Frame 10.<br />
3. Add 156mm to dimension L, hand set teles<strong>co</strong>pic flue<br />
length as indicated in drawing.<br />
4. Using a 3.5mm drill bit, drill two holes in outer air duct<br />
taking care not to pierce plastic inner flue.<br />
5. Fix to length using self tappers provided.<br />
6. Seal outer air duct using the tape provided.<br />
esp8938<br />
Drill hole<br />
esp8939<br />
Measurement to be<br />
taken from this point<br />
L + 145<br />
Measurement to be<br />
taken from this point<br />
Adhere sealing tape<br />
FLUE OUTLET<br />
<strong>Esprit</strong> - Installation and Servicing<br />
19