INSTALLATION<br />

27 FLUE TERMINAL POSITION<br />

The terminal should be positioned so that products of<br />

<strong>co</strong>mbustion can safely disperse at all times.<br />

Pluming may occur at the termination so, where<br />

possible, terminal positions where this <strong>co</strong>uld cause<br />

a nuisance should be avoided.<br />

Minimum dimensions are shown below<br />

<strong>30</strong>0mm<br />

min<br />

<strong>30</strong>0mm<br />

min<br />

625mm<br />

Fixed<br />

rf8393-1<br />

rf8392<br />

<strong>30</strong>0mm<br />

min<br />

FLUE OUTLET<br />

Flat roof - with structure<br />

Terminal Position<br />

Directly below an opening,<br />

air brick, windows, etc.<br />

Below plastic / painted gutters<br />

Painted surface<br />

Below eaves or bal<strong>co</strong>ny<br />

rf8394-1<br />

Minimum Dimension<br />

<strong>30</strong>0 mm<br />

<strong>30</strong>0 mm<br />

<strong>30</strong>0 mm<br />

500 mm<br />

690mm<br />

Fixed<br />

26<br />

<strong>Esprit</strong> - Installation and Servicing