SERVICING<br />

59 FLAME DETECTION ELECTRODE REPLACEMENT<br />

1. Refer to Frame 52.<br />

2. Unplug the flame detection lead from the electrode.<br />

3. Remove the 2 screws holding the flame detection<br />

electrode to the <strong>co</strong>mbustion chamber.<br />

4. Remove the electrode.<br />

5. Fit the new flame detection electrode, using the new<br />

gasket supplied. Check dimensions as shown.<br />

6. Reassemble in reverse order, and check that no damage<br />

to the <strong>co</strong>mbustion chamber insulation has occurred<br />

during the electrode replacement.<br />

7. Check the operation of the boiler. Refer to Frame 52.<br />

3<br />

60 SPARK GENERATOR REPLACEMENT<br />

SERVICING<br />

1. Refer to Frame 52.<br />

2. Dis<strong>co</strong>nnect the leads from the spark<br />

generator and bracket.<br />

3. Remove the M5 screw securing the spark<br />

generator bracket to the flue casting.<br />

4. Remove the 2 M4 screws securing the<br />

spark generator to the bracket.<br />

5. Fit the new spark generator and reassemble<br />

in reverse order.<br />

6. Check operation of the boiler. Refer to<br />

Frame 52.<br />