01.04.2014 Views

Ideal Esprit HE Combi Boilers 24,30,35 User Guide - BHL.co.uk

Ideal Esprit HE Combi Boilers 24,30,35 User Guide - BHL.co.uk

Ideal Esprit HE Combi Boilers 24,30,35 User Guide - BHL.co.uk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SERVICING<br />

82 EXPANSION VESSEL REPLACEMENT - SIDE FLUE APPLICATION<br />

SIDE FLUE APPLICATION AND 450MM ACCESS<br />

AVAILABLE ABOVE T<strong>HE</strong> BOILER<br />

1. Refer to Frame 52.<br />

2. Swing the <strong>co</strong>ntrol panel down into the servicing<br />

position. Refer to Frame 46.<br />

3. Drain the boiler. Refer to Frame 72.<br />

4. Remove the two screws retaining the expansion<br />

vessel bracket at top rear of the boiler.<br />

5. Unscrew the union nut on the vessel water<br />

<strong>co</strong>nnection pipe.<br />

6. Unscrew the extension nut holding the expansion<br />

vessel in place<br />

7. Lift and remove the expansion vessel.<br />

8. Fit the new expansion vessel.<br />

9. Re-assemble in reverse order<br />

10. Refill the boiler. Refer to Frame 32.<br />

11. Check operation of the boiler. Refer to Frame 52.<br />

5<br />

6<br />

SERVICING<br />

83 EXPANSION VESSEL REPLACEMENT - REAR FLUE APPLICATION<br />

REAR FLUE APPLICATION OR 450MM<br />

ACCESS ABOVE T<strong>HE</strong> BOILER NOT AVAILABLE<br />

1. Refer to Frame 52.<br />

2. Swing the <strong>co</strong>ntrol panel down into the servicing<br />

position. Refer to Frame 46.<br />

3. Drain the boiler. Refer to Frame 72.<br />

4. Unscrew all of the gas and water <strong>co</strong>nnection<br />

unions on the boiler side of the valves (including<br />

the <strong>co</strong>ndensate <strong>co</strong>nnection and the pressure<br />

relief valve pipe).<br />

5. Remove the screw from the turret clamp and<br />

remove the clamp.<br />

6. Remove the turret.<br />

7. Lift the <strong>co</strong>mplete boiler from the wall mounting<br />

bracket and place on a flat surface.<br />

8. Remove the bracket retaining the expansion<br />

vessel at the top rear of the boiler.<br />

9. Unscrew the union nut on the vessel water<br />

<strong>co</strong>nnection pipe.<br />

10. Unscrew the extension nut holding the expansion<br />

vessel in place.<br />

11. Remove the expansion vessel.<br />

12. Fit the new expansion vessel.<br />

13. Reassemble in reverse order<br />

14. Refill the boiler. Refer to Frame 32.<br />

15. Check operation of the boiler. Refer to Frame 52.<br />

9<br />

10<br />

58<br />

<strong>Esprit</strong> - Installation and Servicing

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!