61 GAS CONTROL VALVE REPLACEMENT<br />

SERVICING<br />

1. Refer to Frame 52.<br />

2. Swing the <strong>co</strong>ntrol box down into the servicing position.<br />

Refer to Frame 46.<br />

3. Unplug the electrical lead <strong>co</strong>nnection from the gas<br />

<strong>co</strong>ntrol valve and dis<strong>co</strong>nnect the earth wire.<br />

4. Undo the gas inlet pipe union at the gas service <strong>co</strong>ck.<br />

5. Undo the union nut on the outlet of the gas <strong>co</strong>ntrol valve.<br />

6. Remove the back nut retaining the valve to the bottom<br />

panel and withdraw the valve upwards.<br />

7. Fit the new gas <strong>co</strong>ntrol valve.<br />

8. Check operation of the boiler. Refer to Frame 52.<br />

5<br />

6<br />

SERVICING<br />

4<br />

3<br />

62 DIVERTER VALVE ACTUATOR REPLACEMENT<br />

1. Refer to Frame 52.<br />

2. Swing the <strong>co</strong>ntrol box down into the<br />

servicing position. Refer to Frame 46.<br />

3. Remove the electrical <strong>co</strong>nnection.<br />

4. Using a suitable tool pull out the retaining<br />

clip and lift the diverter head from the<br />

brass body.<br />

5. Fit new actuator head and reassemble in<br />

reverse order.<br />

6. Check operation of the boiler. Refer to<br />

Frame 52.<br />